 Overview      Standard Features (HP ProLiant xw25p Blade Workstation)      Standard Features (blade enclosure and interconnects)      Standard Features (Power System and Rack Information)      Standard Features (HP ProLiant xw25p Blade Workstation)      Configuration Information Factory Integrated Models (North America& EMEA)      Options      Memory      Overview (HP Compaq Blade Workstation Client)      Standard Features (HP Compaq Blade Workstation Client)      Options (HP Compaq Blade Workstation Client)      System Details (HP Compaq Blade Workstation Client)      Technical Specifications (HP Compaq Blade Workstation Client)      Technical Specifications - Communications      Technical Specifications - Input/Output Devices      Technical Specifications - Graphics line.gif (50 bytes)

Overview

HP ProLiant xw25p Blade Workstation & HP Blade Workstation Client

HP recommends Windows Vista™ Business
  
42U Rack with 48 HP ProLiant xw25p Blade Workstations
One HP Blade Client with multiple monitors
   
Each HP ProLiant xw25p Blade Workstation handles Office tasks, compute-intensive multitasking, roaming profile, graphical output and fast working profile restores to the HP Blade Workstation Client
   
At A Glance
  • For HP Proliant xw25p Blade Workstation quickspecs, see pages xx - xx
  • For HP Blade Workstation client quickspecs, see pages xx - xx

HP ProLiant xw25p Blade Workstation
42U Rack with HP ProLiant xw25p Blade Workstation System Installed
1. BL p-Class interconnects (2) in HP BladeSystem p-Class blade enclosure (interconnect switch shown)
2. HP ProLiant xw25p blades (8) in HP BladeSystem p-Class blade enclosure
3. HP BladeSystem p-Class 3U power enclosure with hot-plug power supplies (6)
   
At A Glance
  • Performance dual processor blade workstations designed with enterprise availability
  • HP ProLiant xw25p Blade Workstation includes:
  • Dual AMD Opteron 2.6 GHz - 1 MB L2 cache
  • AMD 8131 and 8111 Chipsets
  • 1024 MB or 2048 MB PC3200 Registered ECC 400MHz DDR memory, (2 x 1 Interleaved Memory), expandable to 16 GB
  • One dual port Broadcom 5704 Gigabit NIC embedded with WOL and PXE
  • One additional 10/100 NIC dedicated to iLO Management
  • Smart Array 6i (integrated on system board Controller with optional battery-backed write cache)
  • Wide Ultra3 SCSI Drive Cage standard supports up to two 1" Wide Ultra3 hot plug hard drives
  • Integrated Lights-Out (iLO) Advanced Management (ASIC on motherboard)
  • Plugs vertically into 6U enclosure
  • I/O cable with 2 USB ports, 1 video port, one iLO port and kernel debug port. The I/O cable attaches to the front of the blade workstation. The cable was specifically designed to aid in initial image deployment.
  • Cisco Gigabit Ethernet Switch Module (CGESM) option for Gigabit Ethernet network adapter consolidation.
  • Integrated Access Tool for blade management and enhanced blade documentation including Best Practices and Common Procedures guides
  • HP BladeSystem blade enclosure:
    • Server blades and interconnects blind mate into blade enclosures for network connection and power
    • Server blade enclosure is 6U and holds up to 8 HP ProLiant xw25p Blade Workstations and 2 interconnects
    • Types of interconnects available: GbE Interconnect Switches, Patch Panels
  • HP BladeSystem Power Enclosures:
    • Use BL p-Class sizing tool to determine power based on your configuration
      http://h30099.www3.hp.com/configurator/calc/Power%20Calculator%20Catalog.xls.
    • BL p-Class power enclosure provides shared, external, redundant power
    • Choose the HP BladeSystem p-Class 3U power enclosure or the HP BladeSystem p-Class 1U power enclosure
    • Choose single-phase or three-phase power
    • HP BladeSystem power enclosures with power supplies are not needed if using facility -48VDC ± 10%, in this case purchase facility DC option kit
  • HP BladeSystem p-Class Power Distribution (only required with the 3U power enclosure):
    • Distributes power from the power enclosure to the blade enclosures
    • Four power distribution choices:
    • BL p-Class scalable bus bar
    • BL p-Class mini bus bar
    • BL p-Class power bus box
    • Dual power input kit for mini bus bar (required for support of two power enclosures)
  • HP ProLiant xw25p Blade Workstation, and p-Class blade enclosure, interconnects and power enclosure protected by a limited three year warranty with optional service uplifts available
    NOTE: Power requirements for a HP BladeSystem p-Class-: 200V - 240V AC, 30 amp or facility DC -48V ± 10%.
HP ProLiant xw25p Blade Workstation

+

HP BladeSystem p-Class blade enclosure

+

BL p-Class Interconnects

+

Patch Panel (shown) or
Patch Panel 2
 
GbE Interconnect Switch (shown) or
GbE2 Interconnect Switch or
CGESM Interconnect Switch (fiber or copper-based)

+

BL p-Class power enclosures and power supplies
or
HP BladeSystem p-Class 1U power enclosure and power supplies
or
Facility DC
HP BladeSystem p-Class power distribution (only required with the 3U power enclosure)
or
or
 
Mini bus bar
Bus boxes
     
Scalable bus bar
     
Dual power input kit for mini bus bar
 
Configuration Steps
  • For a complete configuration of the HP ProLiant xw25p Blade Workstation, do the following:
  1. Select desired model, configuration and quantity of HP ProLiant xw25p blade workstations.

    PLUS
  2. Decide how many HP BladeSystem p-Class blade enclosures to purchase (each enclosure can hold up to 8 HP ProLiant xw25p blade workstations):
    HP BladeSystem p-Class blade enclosure with 8 Rapid Deployment Pack licenses (281404-B21)
    Or
    HP BladeSystem p-Class blade enclosure with Rapid Deployment Pack trial (243564-B21)
    Or
    HP BladeSystem p-Class blade enclosure with enhanced backplane components with 8 Rapid Deployment Pack licenses (281404-B22)
    Or
    HP BladeSystem p-Class blade enclosure with enhanced backplane components with 8 Rapid Deployment Pack trial (243564-B22)
    Or
    HP BladeSystem p-Class blade enclosure with enhanced backplane components with 8 HP BladeSystem Management Suite licenses (380625-B22) - includes: a single copy of Systems Insight Manager (SIM) and 8 licenses for each of the following products: Rapid Deployment Pack (RDP), Performance Management Pack (PMP) and the Vulnerability and Patch Management Pack (VPM)
    NOTE: The HP xw25p Blade Workstation does not currently support PMP. Future support is planned.

    Or
    HP BladeSystem p-Class blade enclosure Upgrade Kit (option)(354100-B21)
    NOTE: blade enclosure Upgrade Kit (354100-B21) contains enhanced backplane components and enables a field upgrade of a blade enclosure to support BL p-class blades and provide a single, physical iLO port for the enclosure.


    PLUS
  3. Select an Interconnect Kit. Each Interconnect Kit contains a pair of interconnects except the Cisco GESM which contains a single Switch per kit. One pair of interconnects is required with each blade enclosure:
    Or
    RJ-45 Patch Panel (230766-B21)
    Or
    Quantity (2) Cisco Gigabit Switch Module for HP BladeSystem p-Class Interconnect Kit (with 16 10/100/1000 T/TX/T downlink ports, 2 RJ-45 10/100/1000 T/TX/T uplink ports, and 4 SFP ports) (378926-B21), with or without any combination of up to 4 10/100/1000 T/TX/T RJ-45 SFP Module (378928-B21
    Or
    Quantity (2) Cisco Gigabit Switch Module for HP BladeSystem p-Class Interconnect Kit (with 16 10/100/1000 T/TX/T downlink ports, 2 RJ-45 10/100/1000 T/TX/T uplink ports, and 4 SFP ports populated with 2 10/100/1000 T/TX/T SFP modules) (378927-B21)
    Or
    BL p-Class C GBE2 Interconnect Kit (with 16 10/100/1000 T/TX/T downlink ports, 6 RJ-45 10/100/1000 T/TX/T uplink ports ) (283192-B21)
    Or
    BL p-Class F GBE2 Interconnect (with 16 10/100/1000 T/TX/T downlink ports, 4 LC 1000 SX and 2 RJ-45 10/100/1000 T/TX/T uplink ports) (283193-B21
    Or
    BL p-Class C GBE Interconnect Kit (with 4 RJ-45 10/100/1000 T/TX/T uplink ports and 16 RJ-45 10/100 T/TX downlink ports (249655-B21)
    Or
    BL p-Class F GBE Interconnect Kit (with 4 LC 1000 SX uplink ports and 16 RJ-45 10/100 T/TX downlink ports) (279720-B21)

    PLUS
  4. Select a HP BladeSystem p-Class power enclosure and power supplies based on configuration. Use p-Class sizing tool to help determine power configuration:
    http://h30099.www3.hp.com/configurator/calc/Power%20Calculator%20Catalog.xls
    .
    NOTE: Power enclosures and supplies are not needed if using facility DC (-48V ± 10%).

    Single phase 3U power enclosure with four power supplies (Single-phase 3U power enclosure holds a max of four power supplies) (NA/JPN- 239162-001) (INTL - 239162-421)
    Or
    Three-phase 3U power enclosure with six power supplies (Three-phase 3U power enclosure holds a max of six power supplies) (NA/JPN- 230769-001) (INTL - 230769-421)
    NOTE: 3U Power enclosures and supplies can also be purchased separately see options list

    Or
    1U power enclosure with six power supplies (378284-B21)
    Or
    1U power enclosure with two power supplies (380314-B21)
    NOTE: Additional power supplies can also be purchased separately - see options list below.


    PLUS
  5. Select power distribution (only required with 3U power enclosures):
    Scalable bus bar - Supports up to 5 blade enclosures* (240560-B21)
    Or
    Mini bus bar - Supports up to 3 blade enclosures* (240559-B21)
    Or
    Power Bus Box - Supports only 1 blade enclosure* (240562-B21)
    Dual Power Input Kit for Mini Bus Bar - required for support of two power enclosures. (364565-B21)
    Or
    HP Modular Distribution Unit 40 Amp (NA/JPN) (P/N 252663-D75)**
    Or
    HP Modular Distribution Unit 40 Amp (Int'l) (P/N 252663-B34)**
    Or
    HP Modular Distribution Unit 32 Amp (Int'l) (P/N 252662-B33)**
    Or
    HP Modular Distribution Unit 24 Amp (NA/JPN) (P/N 252663-D74)**
    *NOTE: Maximum depends upon power input
    **NOTE: The Modular Distribution Unit Kits excludes the extension bars as they are not required with the HP BladeSystem p-class 1U power enclosure.
contents
 Overview      Standard Features (HP ProLiant xw25p Blade Workstation)      Standard Features (blade enclosure and interconnects)      Standard Features (Power System and Rack Information)      Standard Features (HP ProLiant xw25p Blade Workstation)      Configuration Information Factory Integrated Models (North America& EMEA)      Options      Memory      Overview (HP Compaq Blade Workstation Client)      Standard Features (HP Compaq Blade Workstation Client)      Options (HP Compaq Blade Workstation Client)      System Details (HP Compaq Blade Workstation Client)      Technical Specifications (HP Compaq Blade Workstation Client)      Technical Specifications - Communications      Technical Specifications - Input/Output Devices      Technical Specifications - Graphics line.gif (50 bytes)

Standard Features (HP ProLiant xw25p Blade Workstation)

Processor

Dual AMD Opteron Model 252 processor 2.6 GHz/1 GHz - 1MB


Cache Memory 1 MB Level 2 Cache

Chipset AMD 8131 and 8111 chipsets

Memory Standard 2048 MB or 4096 MB of 2-way interleaved PC3200 DDR SDRAM running at 400MHz (depending on model)
Maximum 16 GB
NOTE: Memory must be installed in pairs.

Network Adapter Three network adapters total:
One dual port Broadcom 5704 Gigabit NIC embedded with WOL and PXE
One 10/100 iLO NIC dedicated to management

Manageability Integrated Lights-Out (iLO) Management Advanced (ASIC on the System Board)

Internal Storage Maximum 600 GB (internal drive cage) (2 x 300 GB Wide Ultra320, 1" drive)

Expansion Slots No PCI slots all features are integrated
I/O cable connectors:
(2)USB ports, (1) video port, (1) iLO port and (1) kernel debug port
Connects to the front of the server blade for aid in 1st server blade deployment and troubleshooting
Tested USB devices (keyboard, mouse, floppy) are listed in the "Options" section of this QuickSpecs
Diagnostic Cable Connectors:
(1) iLO port and (1) kernel debug port
(2) I/O cables ship with every blade enclosure
Connects to the front of the blade for aid in troubleshooting
Graphics:
Internal NVIDIA MXM-II Quad display PCIe x16 graphics accelerator
contents
 Overview      Standard Features (HP ProLiant xw25p Blade Workstation)      Standard Features (blade enclosure and interconnects)      Standard Features (Power System and Rack Information)      Standard Features (HP ProLiant xw25p Blade Workstation)      Configuration Information Factory Integrated Models (North America& EMEA)      Options      Memory      Overview (HP Compaq Blade Workstation Client)      Standard Features (HP Compaq Blade Workstation Client)      Options (HP Compaq Blade Workstation Client)      System Details (HP Compaq Blade Workstation Client)      Technical Specifications (HP Compaq Blade Workstation Client)      Technical Specifications - Communications      Technical Specifications - Input/Output Devices      Technical Specifications - Graphics line.gif (50 bytes)

Standard Features (blade enclosure and interconnects)

HP BladeSystem p-Class blade enclosures and ProLiant BL p-Class Interconnects
HP BladeSystem
p-Class blade enclosures
6U (10.5-inch), 19-inch wide
Holds up to 8 HP ProLiant xw25p Blade Workstations
10 bays per blade enclosure 8 bays for blades
2 outside bays for interconnect modules (RJ-45 Patch Panel, RJ-45 Patch Panel 2, GbE Interconnect Switch, GbE2 Interconnect Switch or CGESM Interconnect Switch)
Blades blind mate into the blade enclosure backplane for power and data connections
NOTE: Blade Enclosure Upgrade Kit (354100-B21) contains enhanced backplane components and enables a field upgrade of a blade enclosure to support specific HP ProLiant xw25p blade workstation models and provide a single, physical iLO port for the enclosure.
Blade management module attached to the back of each HP BladeSystem p-Class 6U blade enclosure to report events all blades and provide asset and inventory information

HP BladeSystem
p-Class Power Requirements
Redundant 200V - 240V AC, 30 amp single-phase for NA and International
Redundant 208V 30amp 3-phase 4 wire, NA
Redundant 380 - 415V 20A 3-phase 5 wire, Intl
Redundant -48VDC ± 10%

ProLiant BL p-Class
Interconnect Switch
Option

(Every HP BladeSystem p-Class blade enclosure requires two interconnect switches OR two RJ-45 patch panels)

Provides up to a 32 to 1 networking cable reduction per enclosure. Each interconnect switch (two per enclosure) reduces up to sixteen internal blade network (NIC) ports to six external ports (four on a modular rear mounting interconnect module and two on the switch front panel). This provides a total of twelve external ports per blade enclosure. Only one to all twelve external ports may be used per blade enclosure.

The Cisco Gigabit Ethernet Switch Module (CGESM) Interconnect Kits are for applications that require network adapter consolidation to 1000 Mbps (Gigabit Ethernet) in a Cisco infrastructure.

  • The Cisco Gigabit Ethernet Switch Module Interconnect kit includes one CGESM Interconnect Switch or one CGESM with four (4) RJ-45 10/100/1000 T/TX/T Small Form Factor Pluggable (SFP) Modules
  • Quantity 2 Cisco Gigabit Ethernet Switch Module Interconnect kits provide two CGESM Interconnect Switches providing any combination of up to twelve (12) RJ-45 10/100/1000 T/TX/T or Fiber SX external ports per blade enclosure.

The GbE2 Interconnect Kits (C GBE2 and F GBE2) are for applications that require network adapter consolidation to 1000 Mbps (Gigabit Ethernet).

  • The ProLiant BL p-Class F GBE2 Interconnect Kit includes two GbE2 Interconnect Switches and two QuadSX Interconnect Modules that provide eight (8) LC 1000 SX and four (4) RJ-45 10/100/1000 T/TX/T external ports per blade enclosure.
  • The ProLiant BL p-Class C GBE2 Interconnect Kit includes two GbE2 Interconnect Switches and two QuadT2 Interconnect Modules that provide twelve (12) RJ-45 10/100/1000 T/TX/T external ports per blade enclosure.

The GbE Interconnect Kits (C GBE and F GBE) are for applications that require network adapter consolidation to 100 Mbps (Fast Ethernet).

  • The ProLiant BL p-Class F GBE Interconnect Kit includes two GbE Interconnect Switches and two DualTSX Interconnect Modules that provide four (4) LC 1000 SX and eight (8) RJ-45 10/100 T/TX external ports per blade enclosure.
  • The ProLiant BL p-Class C GBE Interconnect Kit includes two GbE Interconnect Switches and two QuadT Interconnect Modules that provide four (4) RJ-45 10/100/1000 T/TX/T and eight (8) RJ-45 10/100 T/TX external ports per blade enclosure.
Also included (per Interconnect Switch):
  • One (1) RS-232 DB-9 front panel out-of-band management port
  • Redundant crosslink ports connecting the two interconnect switches
  • Redundant power inputs and on-board redundant fans
  • Hot-plug and hot- remove with configuration retention and no need to cable/re-cable
  • Power ON, management, and per port status and speed LED indicators
  • Reset/power momentary push-button switch
  • HP ProLiant BL Interconnect Switch Management Utilities and User Documentation CD
  • Fully pre-configured for rapid deployment and immediate operation

The GbE Interconnect Kits (C GBE and F GBE) are for applications that require network adapter consolidation to 100 Mbps (Fast Ethernet).

  • The ProLiant BL p-Class F GBE Interconnect Kit includes two GbE Interconnect Switches and two DualTSX Interconnect Modules that provide four (4) LC 1000 SX and eight (8) RJ-45 10/100 T/TX external ports per blade enclosure.
  • The ProLiant BL p-Class C GBE Interconnect Kit includes two GbE Interconnect Switches and two QuadT Interconnect Modules that provide four (4) RJ-45 10/100/1000 T/TX/T and eight (8) RJ-45 10/100 T/TX external ports per blade enclosure.
ProLiant BL Interconnect Switch Management System and Utilities:
Full featured web-based and scriptable command line (CLI) interfaces, password protected multi-level user accounts, Telnet, SNMP, BootP client, port mirroring, port-based VLANs and VLAN tagging, EtherChannel compatible multi-port trunking, network time protocol, spanning tree protocol, broadcast/multicast storm control, flow control, human readable/writeable configuration file, TFTP client, IP address security restrictions, auto-MDI/MDIX, auto-negotiation and auto-sensing of speed and duplex mode, and more.

ProLiant BL p-Class
RJ-45 Patch Panel

(Two patch panels per kit) (Every BL p-Class blade enclosure requires two Interconnect switches OR two RJ-45 patch panels)

6U (10.5-inch), Plugs into HP BladeSystem p-Class 6U blade enclosures

Used to pass NIC signals from all blade workstations in blade enclosure out as RJ-45 connections

Supports Gigabit Ethernet network adapters

16 RJ-45 connectors on the back of each BL p-Class 6U RJ-45 Patch Panel (32 RJ-45 connections per blade enclosure)


Required Network
Cabling
10Base-T Categories 3, 4 or 5 UTP (100 meters)
EIA/TIA-568 100-ohm STP (100 meters)
100Base-TX Category 5 UTP (100 meters)
EIA/TIA-568 100-ohm STP (100 meters)
1000Base-T Category 5 UTP (100 meters)
EIA/TIA-568 100-ohm STP (100 meters)
1000Base-SX 50/125 µm Multimode Fiber, 400 MHz/Km (500 meters)
50/125 µm Multimode Fiber, 500 MHz/Km (550 meters)
62.5/125 µm Multimode Fiber, 160 MHz/Km (220 meters)
62.5/125 µm Multimode Fiber, 200 MHz/Km (275 meters)
NOTE: For cabling information, refer to the Web site at:
http://www.compaq.com/products/servers.
contents
 Overview      Standard Features (HP ProLiant xw25p Blade Workstation)      Standard Features (blade enclosure and interconnects)      Standard Features (Power System and Rack Information)      Standard Features (HP ProLiant xw25p Blade Workstation)      Configuration Information Factory Integrated Models (North America& EMEA)      Options      Memory      Overview (HP Compaq Blade Workstation Client)      Standard Features (HP Compaq Blade Workstation Client)      Options (HP Compaq Blade Workstation Client)      System Details (HP Compaq Blade Workstation Client)      Technical Specifications (HP Compaq Blade Workstation Client)      Technical Specifications - Communications      Technical Specifications - Input/Output Devices      Technical Specifications - Graphics line.gif (50 bytes)

Standard Features (Power System and Rack Information)

HP BladeSystem
p-Class Power System and Rack Information
NOTE: To determine power configuration please refer to the HP BladeSystem p-Class Overview and Planning Whitepaper and sizing tool at
http://h18000.www1.hp.com/products/servers/proliant-bl/p-class/20p/index.html.

HP BladeSystem
p-Class 3U Power Enclosure
3U (5.25-inch), 19-inch wide, 29-inch deep (0.48-meter wide, 0.74-meter deep), Dual input single phase and three phase models available.
HP BladeSystem p-Class 3U power enclosure provides external, shared hot-plug power. Each three-phase power enclosure houses up to six hot-plug power supplies each single-phase power enclosures hold up to four hot-plug power supplies to power the xw Blade Workstations and interconnects
Please use the sizing utility to determine the power needed for each configuration
http://www.hp.com/go/bladesystem/powercalculator.
NOTE: Power enclosures and power supplies are not needed if using facility DC (-48V DC ± 10%). If using facility DC, only Facility DC Power Connection kit part number (240563-B21) is needed.

HP BladeSystem
p-Class 1U Power Enclosure
1U (1.75-inch), 19-inch wide, 29-inch deep (0.48-meter wide, 0.74-meter deep), Multi-input single phase or three phase operation.
HP BladeSystem p-Class 1U power enclosure provides external, hot-plug power. Each 1U power enclosure houses up to six hot-plug power supplies to power up to one Blade Workstation enclosure, fully populated with xw Blade Workstations and interconnects.
Please use the sizing utility to determine the power needed for each configuration
http://www.hp.com/go/bladesystem/powercalculator.
NOTE: Power enclosures and power supplies are not needed if using facility DC (-48V DC ± 10%). If using facility DC, only Facility DC Power Connection kit part number (240563-B21) is needed.

HP BladeSystem
p-Class Power Distribution

(only required with 3U power enclosures)

In the HP BladeSystem p-Class infrastructure, redundant -48 VDC power (from the power enclosures or facility DC power) is distributed from the power enclosures to the blade enclosures through the bus bar system. Hinges attach the HP BladeSystem bus bars to the rails in a rack. The bus bars swing open from the center to enable easy rear access to the blade workstations and network cables. Power is distributed redundantly through independent A- and B-sided bus bars.
Three different power distribution solutions are available depending on the maximum number of blade enclosures planned for the rack:
  • HP BladeSystem p-Class scalable bus bar
  • HP BladeSystem p-Class mini bus bar
  • HP BladeSystem p-Class power bus box
NOTE: To support a full 42U rack of HP ProLiant xw25p Blade Workstations (6 blade enclosures), two mini bus bars are needed.
 
Power Enclosures Supported
blade enclosures Supported
Max. Rack Space Occupied
Scalable Bus Bar
1 or 2
up to 5
36U
Mini Bus Bar
1 or 2
up to 3
21U
Power Bus Box

1

Dual power input kit for mini bus bar option (364565-B21) required to support two power enclosures.

NOTE: To support a full 42U rack of xw Blade Workstations, use two stacked pairs of mini bus bars.

1
9U

Required Power Source Two 30amp redundant power feeds per power enclosure
Connectors
-NEMA receptacles (NA/Japan)
NA 1-phase L6-30, 250v, 30A 3-wire
NA 3-phase L15-30, 250V, 30A, 4-wire
-IEC 309 Pin & Sleeve connectors (International)
Intl 1-phase 250V, 32A, 3- pin (2 pole + ground)
Intl 3-phase 380-415V, 32A, 5--pin (4 pole + ground)
Optimized for power cabling from bottom and network cabling from top
contents
 Overview      Standard Features (HP ProLiant xw25p Blade Workstation)      Standard Features (blade enclosure and interconnects)      Standard Features (Power System and Rack Information)      Standard Features (HP ProLiant xw25p Blade Workstation)      Configuration Information Factory Integrated Models (North America& EMEA)      Options      Memory      Overview (HP Compaq Blade Workstation Client)      Standard Features (HP Compaq Blade Workstation Client)      Options (HP Compaq Blade Workstation Client)      System Details (HP Compaq Blade Workstation Client)      Technical Specifications (HP Compaq Blade Workstation Client)      Technical Specifications - Communications      Technical Specifications - Input/Output Devices      Technical Specifications - Graphics line.gif (50 bytes)

Standard Features (HP ProLiant xw25p Blade Workstation)

ProLiant Essentials Foundation Pack Software for ProLiant Blades ProLiant Essentials Rapid Deployment Pack Rapid Deployment Pack (RDP) is an automated deployment and provisioning solution for all blades. RDP includes the Altiris Deployment Solution. Every RDP CD includes 10-node trial licenses for evaluation purposes. RDP requires a license for each blade deployed and is available for purchase with blades. For more information, visit http://www.hp.com/servers/rdp.
HP Systems Insight Manager HP Systems Insight Manager (HP SIM) help maximize system uptime and performance and reduce system maintenance costs by providing proactive notification of problems before those problems result in unplanned downtime or reduced productivity. HP SIM is easy to set up to work with the Insight Management Agents, integrated Light-Out and Remote Insight Light-Out Edition, and Version Control Agents to deliver robust fault, configuration, and asset management as well as remote administration. With HP Systems Insight Manager customers will also be able to take advantage of role-based security; the ability to manage ProLiant, Integrity, and HP9000 systems; and plug-ins for storage, client, printer, and power management as well as blade rapid deployment, performance management, and workload management. For more details on HP Systems Insight Manager visit http://www.hp.com/go/hpsim.
Management Agents The Management Agents form the foundation for HP's Intelligent Manageability strategy. They provide direct, browser-based access to in-depth instrumentation built into HP Blade Workstations and clients, and send alerts to HP Systems Insight Manager and other enterprise management applications in case of subsystem or environmental failures. For additional information about the Management Agents and other management products from HP, please visit the management Web site at http://www.hp.com/servers/manage.
Subscriber's Choice Subscriber's Choice Driver and Support Alerts/Notifications is a web-based email subscription service that provides software and driver change notifications for HP products. Sign up at http://www.hp.com/go/subscriberschoice
and customize your profile to receive various new alerts as they become available, on a weekly or monthly basis.
ROMPaq, support software, and
configuration utilities
The latest software, drivers, and firmware fully optimized and tested for your workstation blade and options is downloadable from Software and Drivers download pages, linked from http://www.hp.com/go/support.
Insight Diagnostics Offline Edition The most advanced configuration analysis, reporting and troubleshooting utilities used by HP and at your fingertips, available in documentation and diagnostics CD that ships with the system.

OS Support Microsoft® Windows® XP Professional Blade PC Edition

NOTE: For a more complete and up-to-date listing of supported OSs and versions, please visit our OS Support Matrix at: http://www.hp.com/go/supportos.
NOTE: For an up-to-date listing of the latest drivers available for the ProLiant BL p-Class, please see: http://www.compaq.com/support/files/server/us/index.html.


Intelligent Manageability Integrated Lights-Out Advanced (iLO)
Graphical Remote Console *
Virtual CD-ROM*
Virtual Floppy *
Virtual Power Button Control
Dedicated LAN Connectivity
Automatic IP Configuration via DHCP/DNS/WINS
Industry Standard 128-bit Secure Sockets Layer (SSL) Security
IML and iLO Event Logging
Support for 12 user accounts with customizable access privileges
HP Systems Insight Manager
Redundant ROM
Remote Flash ROM
Redundant Power Supply Utility
Advanced Configuration and Power Interface (ACPI) compliant, does not support sleep states S1 and S3
Integrated Management Log (IML)
Network adapter teaming set-up utility
*NOTE: Advanced features such as Graphical Remote Console and Virtual Floppy are included with the blade.

Availability Power redundancy: Redundant AC feeds into power enclosures, redundant DC feeds from power enclosure to blade enclosures,
N + N redundant power supplies
Two hot-plug SCSI hard drive bays and integrated RAID (Smart Array 5i Plus) on every blade (Battery-backed write cache is optional.)
Redundant ROM on each blade
ECC Memory
Network adapter teaming (network fault tolerance, transmit load balancing, switch-assisted load balancing)
Interconnects Switch Availability
  • Hot-plug and hot- remove with configuration retention and no need to cable/re-cable
  • Two network connections per blade bay (four NICs total) routed to two redundant interconnect switches
  • Redundant Ethernet inter-switch communication with two sets of redundant Ethernet uplink ports per each interconnect switch
  • Redundant front panel ports per each interconnect switch for diagnostics, management, and additional uplinks
  • Redundant serial ports
  • Compatibility with PVST+ (CGESM or GbE2 switch) and 802.1D Spanning tree protocol support for loop-free path redundancy
  • Static IEEE 802.3ad (EtherChannel compatible) trunking with automatic port load balancing and failover
  • Redundant configuration files and operating system firmware images in memory (GbE2 switch)
  • Redundant fans per each interconnect switch
  • Redundant 1+1 power to each interconnect switch
  • Support for ProLiant network adapter teaming
  • Redundant configurable community strings and SNMP trap manager hosts
  • Redundant configurable syslog server, DNS server, and default gateways (GbE2 switch)

Security Power-on password
Administrator's password
Integrated Lights-Out has 12 customizable user accounts and SSL encryption
Integrated Lights-Out can be disabled via a Global Setting
Interconnect switch multilevel user names and passwords, management interface time out period setting, SSH*, SCP secure copy protocol*, port-based IEEE 802.1Q tagged VLANs, RADIUS user authentication and authorization*, and IP address restriction
*NOTE: CGESM and GbE2 Interconnect Switch only

Minimum Rack Requirements Mounts in ProLiant, and Telco racks and Third Party racks that meet the following criteria:
  • Compatible with 19-inch Standard EIA rail sets
  • EIA rail-to-rail depth is 29 - 30"
  • Cabinet depth must be at least 36-inch deep overall (Additional min. 3.5-inch clearance from rear RETMA rail to rear door, inclusive in the 36-inch overall depth)
  • Ample room for top and bottom cable egress (approximately 8 square inches for full rack configuration with patch panel)
  • Must be capable of supporting 1600 lb (for full rack configuration)
  • Perforated front and rear doors to accommodate front-to-back cooling
  • Must have 65% open perforation on blade enclosure doors to support airflow requirements
  • Optimized for use with the HP 10000 Series racks
NOTE: If using Compaq 7000 Series rack, Rack Extension Kit and High Air Flow Rack Door options are required.

Rack Airflow Requirements Rack 10000 series Cabinets
The increasing power of new high-performance processor technology requires increased cooling efficiency for rack-mounted blades. The 10000 Series Racks provide enhanced airflow for maximum cooling, allowing these racks to be fully loaded with blades using the latest processors.
CAUTION: If a third-party rack is used, observe the following additional requirements to ensure adequate airflow and to prevent damage to the equipment:
  • Front and rear doors: If your 42U rack includes closing front and rear doors, you must allow 830 square inches (5,350 sq cm) of hole evenly distributed from top to bottom to permit adequate airflow (equivalent to the required 64 percent open area for ventilation).
  • Side: The clearance between the installed rack component and the side panels of the rack must be a minimum of 2.75 inches (7 cm).
CAUTION: Always use blanking panels to fill all remaining empty front panel U-spaces in the rack. This arrangement ensures proper airflow. Using a rack without blanking panels results in improper cooling that can lead to thermal damage.
NOTE: For additional information, refer to the Setup and Installation Guide or the Documentation CD provided with the blade, or to the blade documentation located in the Support section at the following URL: http://www.hp.com/servers/bl25p.

Service and Support

Three-year limited warranty, including hardware diagnostic support, pre-failure warranty (coverage of hard drives, memory and processors). The warranty is fully supported by HP Services and a worldwide network of resellers and service providers. In addition 90-day's getting started software telephone support may be covered under the warranty or available for an additional fee. Enhancements to warranty services are available through HP Care Pack services.

NOTE: Workstation Blade Limited Warranty includes 3 year Parts, 3 year Labor, 3-year on-site support.
NOTE: Blade Enclosure and Interconnects Limited Warranty is for 1 year Parts, 1 year Labor, 1-year on-site support

Care Pack services provide a range of life cycle support options that let you choose the service levels that meet your business requirements, from basic to mission-critical.

A full range of HP Care Pack hardware and software services are available including:

  • Installation and start up (availability TBC)
  • Education courses
  • Extended onsite hardware coverage hours from same business day, 9 hours, 5 days a week
  • Comprehensive range of software technical support for Microsoft Windows XP -based IT solutions helping to deliver high level of application availability. Response times range from 30 mins for critical problems to 2 hours.
  • System Management, Performance Services and Mission Critical Support Solution

NOTE: Support information for the Blade Workstation is available at the following web page: http://www.hp.com/support/xw25p
NOTE: Support information for the Blade Client is available at the following web page: http://www.hp.com/support/BWClient

contents
 Overview      Standard Features (HP ProLiant xw25p Blade Workstation)      Standard Features (blade enclosure and interconnects)      Standard Features (Power System and Rack Information)      Standard Features (HP ProLiant xw25p Blade Workstation)      Configuration Information Factory Integrated Models (North America& EMEA)      Options      Memory      Overview (HP Compaq Blade Workstation Client)      Standard Features (HP Compaq Blade Workstation Client)      Options (HP Compaq Blade Workstation Client)      System Details (HP Compaq Blade Workstation Client)      Technical Specifications (HP Compaq Blade Workstation Client)      Technical Specifications - Communications      Technical Specifications - Input/Output Devices      Technical Specifications - Graphics line.gif (50 bytes)

Configuration Information Factory Integrated Models (North America& EMEA)

ProLiant xw25p Blade Workstation 2.6 GHz-1 MB, 4 GB (2P), 146 GB
390294-B21
Processor(s) (1) AMD Opteron Model 252 2.6 GHz standard (up to 2 supported)
Cache Memory 1 MB Level 2 writeback per processor
Memory 4 GB (Standard) to 16 GB (Maximum) of 2-way interleaved capable PC3200 DDR SDRAM running at 400MHz (4x 1 GB)
Network Adapter Two Gigabit NICs (embedded) with WOL and PXE
One additional 10/100 NIC dedicated to iLO Management
Storage Controller Smart Array 6i Controller (integrated on system board)
Hard Drives 146 GB Ultra320 SCSI 10K RPM
Internal Storage Up to 2 Ultra320 SCSI drives
Optical Drive None
Form Factor Plugs vertically into HP BladeSystem p-Class blade enclosure

ProLiant xw25p Blade Workstation 2.6Ghz-1MB, 2GB (2P), 72 GB
390293-B21
Processor(s) (1) AMD Opteron Model 252 2.6 GHz standard (up to 2 supported)
Cache Memory 1 MB Level 2 writeback per processor
Memory 2 GB (Standard) to 16 GB (Maximum) of 2-way interleaved capable PC3200 DDR SDRAM running at 400MHz (4x512 MB)
Network Adapter Two Gigabit NICs (embedded) with WOL and PXE
One additional 10/100 NIC dedicated to iLO Management
Storage Controller Smart Array 6i Controller (integrated on system board)
Hard Drives 72 GB Ultra320 SCSI 10K RPM disk
Internal Storage Up to 2 Ultra320 SCSI drives
Optical Drive None
Form Factor Plugs vertically into HP BladeSystem p-Class blade enclosure
contents
 Overview      Standard Features (HP ProLiant xw25p Blade Workstation)      Standard Features (blade enclosure and interconnects)      Standard Features (Power System and Rack Information)      Standard Features (HP ProLiant xw25p Blade Workstation)      Configuration Information Factory Integrated Models (North America& EMEA)      Options      Memory      Overview (HP Compaq Blade Workstation Client)      Standard Features (HP Compaq Blade Workstation Client)      Options (HP Compaq Blade Workstation Client)      System Details (HP Compaq Blade Workstation Client)      Technical Specifications (HP Compaq Blade Workstation Client)      Technical Specifications - Communications      Technical Specifications - Input/Output Devices      Technical Specifications - Graphics line.gif (50 bytes)

Options

ProLiant Essentials
Value Pack Software
Rapid Deployment Pack, 10 User, V1.x
269817-B21
NOTE: This license allows 10 blades to be managed and deployed via the Deployment Server.
NOTE: Not necessary if you purchase the blade enclosure with 8 Rapid Deployment Pack licenses 281404-B21.
NOTE: Rapid Deployment pack is now available in Linux only environments.
Rapid Deployment Pack, 10 User, V1.x (Japan)
269817-291
NOTE: This license allows 10 blades to be managed and deployed via the Deployment Server.
NOTE: Not necessary if you purchase the blade enclosure with 8 Rapid Deployment Pack licenses 281404-B21.
NOTE: Rapid Deployment pack is now available in Linux only environments.
Rapid Deployment Pack, 1 User, V1.x
267196-B21
NOTE: This license allows 1 blade to be managed and deployed via the Deployment Server.
NOTE: Not necessary if you purchase the blade enclosure with 8 Rapid Deployment Pack licenses 281404-B21.
NOTE: Rapid Deployment pack is now available in Linux only environments.
Rapid Deployment Pack, 1 User, V1.x (Japan)
267196-291
NOTE: This license allows 1 blade to be managed and deployed via the Deployment Server.
NOTE: Not necessary if you purchase the blade enclosure with 8 Rapid Deployment Pack licenses 281404-B21.
NOTE: Rapid Deployment pack is now available in Linux only environments.
Flexible Quantity License Kit
302127-B21
License-Only - for use with a Master License Agreement
302128-B21

Memory
(SDRAM DIMMs)
4GB of Advanced ECC PC3200 DDR-400 SDRAM DIMM Memory Kit (2 x 2 GB)
379300-B21
2GB of Advanced ECC PC3200 DDR-400 SDRAM DIMM Memory Kit (2 x 1 GB)
376639-B21
1GB of Advanced ECC PC3200 DDR-400 SDRAM DIMM Memory Kit (2 x 512 MB)
376638-B21

Hard Drives Ultra320 SCSI - Universal Hot Plug
300 GB 10,000 rpm U320 Universal Hard Drive (1")
350964-B22
146.8 GB 10,000 rpm U320 Universal Hard Drive (1")
286716-B22
72.8 GB 10,000 rpm U320 Universal Hard Drive (1")
286714-B22
72.8 GB 15,000 rpm U320 Universal Hard Drive (1")
286778-B22
146.8 GB 15,000 rpm U320 Universal Hard Drive (1")
347708-B22
36.4 GB 15,000 rpm U320 Universal Hard Drive (1")
286776-B22

HP BladeSystem
p-Class blade enclosures
HP BladeSystem p-Class blade enclosure with enhanced backplane components and the HP BladeSystem Management Suite
NOTE: Includes a HP BladeSystem p-Class blade enclosure with enhanced backplane components, a single copy of Systems Insight Manager (SIM) and 8 licenses for each of the following products: Rapid Deployment Pack (RDP), Performance Management Pack (PMP) and the Vulnerability and Patch Management Pack (VPM).
NOTE: The HP ProLiant xw25p Blade Workstation does not currently support PMP. Future support is planned.
380625-B22
HP BladeSystem p-Class blade enclosure (ProLiant Essentials Rapid Deployment Pack Trial)
243564-B21
HP BladeSystem p-Class blade enclosure (8 ProLiant Essentials Rapid Deployment Pack Licenses)
281404-B21
HP BladeSystem p-Class blade enclosure with enhanced backplane components (ProLiant Essentials Rapid Deployment Pack Trial)
243564-B22
HP BladeSystem p-Class blade enclosure with enhanced backplane components (8 ProLiant Essentials Rapid Deployment Licenses)
NOTE: HP BladeSystem p-Class Enhanced blade enclosures with enhanced backplane components may be required depending on which HP ProLiant xw25p Blade Workstation model is selected.
For additional information regarding blade enclosure Compatibility, please visit the following URL: http://www.hp.com/go/bladesystem/enclosure/compatibility
281404-B22
HP BladeSystem p-Class blade enclosure Upgrade Kit (option)
NOTE: blade enclosure Upgrade Kit (354100-B21) contains enhanced backplane components and enables a field upgrade of a blade enclosure to support BL p-class blades and provide a single, physical iLO port for the enclosure.
354100-B21

HP BladeSystem
p-Class Interconnects
ProLiant BL p-Class RJ-45 Patch Panel 2 with Fibre pass-through (pair) (required for FC connectivity)
306465-B21
NOTE: Only one interconnect kit required per blade enclosure.
ProLiant BL p-Class RJ-45 Patch Panel (pair)
230766-B21
NOTE: Only one interconnect kit required per blade enclosure.
ProLiant BL p-Class C GBE2 Interconnect Kit (with pair of GbE2 Interconnect Switches and two QuadT2 Interconnect Modules)
283192-B21
NOTE: Only one interconnect kit required per blade enclosure.
ProLiant BL p-Class F GBE2 Interconnect Kit (with pair of GbE2 Interconnect Switches and two QuadSX Interconnect Modules)
283193-B21
NOTE: Only one interconnect kit required per blade enclosure.
Cisco Gigabit Ethernet Switch Module for HP BladeSystem p-Class Interconnect Kit Base Unit only
378926-B21
NOTE: Two CGESM interconnect kits required per blade enclosure.
Cisco Gigabit Ethernet Switch Module for HP BladeSystem p-Class Interconnect Kit Base Unit (populated with two RJ-45 10/100/1000 T/TX/T Small Form Factor Pluggable (SFP) Modules
378927-B21
NOTE: Two CGESM interconnect kits required per blade enclosure.
Cisco RJ-45 10/100/1000 T/TX/T SFP Module
378928-B21
ProLiant BL p-Class C GBE Interconnect Kit (with pair of GbE Interconnect Switches and two QuadT Interconnect Modules)
249655-B21
NOTE: Only one interconnect kit required per blade enclosure.
NOTE: The GbE Interconnect Switch supports blade NIC speeds to 100 Mbps. It is recommended that a patch panel or GbE2 Interconnect Switch option be used if blade NIC speeds to 1000 Mbps are required.
NOTE: To meet applicable radio frequency (RF) emission limits, the sidewall panels on the ends of any individual rack or a series of coupled racks and the front and rear doors must be installed in any racks containing more than one ProLiant BL p-Class GbE Interconnect Kit.
ProLiant BL p-Class F GBE Interconnect Kit (with pair of GbE Interconnect Switches and two DualTSX Interconnect Modules)
279720-B21
NOTE: Only one interconnect kit required per blade enclosure.
NOTE: The GbE Interconnect Switch supports NIC speeds to 100 Mbps. It is recommended that a patch panel option be used if blade NIC speeds to 1000 Mbps are required.
NOTE: To meet applicable radio frequency (RF) emission limits, the sidewall panels on the ends of any individual rack or a series of coupled racks and the front and rear doors must be installed in any racks containing more than one ProLiant BL p-Class GbE Interconnect Kit.

HP BladeSystem
p-Class Interconnects
NOTE: Use p-Class sizing tool to help determine power configuration:
http://h30099.www3.hp.com/configurator/powercalcs.asp
Single Phase 3U Power Enclosure with 4 power supplies (NA/JPN)
(Single Phase 3U Power Enclosure holds a maximum of 4 power supplies; no need to order additional power supplies with this option kit)
239162-001
Single Phase 3U Power Enclosure with 4 power supplies (Int'l)
(Single Phase 3UPower Enclosure holds a maximum of 4 power supplies; no need to order additional power supplies with this option kit)
239162-421
3 Phase 3U Power Enclosure with 6 power supplies (NA/JPN)
(3 Phase 3U Power Enclosure holds a maximum of 6 power supplies; no need to order additional power supplies with this option kit)
230769-001
3 Phase 3U Power Enclosure with 6 power supplies (Int'l)
(3 Phase 3U Power Enclosure holds a maximum of 6 power supplies; no need to order additional power supplies with this option kit)
230769-421
Single 3U Phase Power Enclosure (empty) (NA/JPN)
(Holds up to 4 power supplies; power supplies are not included in this kit)
231710-001
Single 3U Phase Power Enclosure (empty) (Int'l)
(Holds up to 4 power supplies; power supplies are not included in this kit)
231710-421
3 Phase 3U Power Enclosure (empty) (NA/JPN)
(Holds up to 6 power supplies; power supplies are not included in this kit)
231709-001
3 Phase 3U Power Enclosure (empty) (Int'l)
(Holds up to 6 power supplies; power supplies are not included in this kit)
231709-421
Single 3U Power Supply
239161-B21
1U Power Enclosure with six power supplies
378284-B21
1U Power Enclosure with two power supplies
380314-B21
Single 1U Power Supply
380312-B21
Facility DC Power Connection
240563-B21

Power Distribution

(only required with 3U power enclosures)

HP BladeSystem p-Class Scalable Bus Bar
240560-B21
HP BladeSystem p-Class Mini Bus Bar
240559-B21
HP BladeSystem p-Class Bus Power Box
240562-B21
Dual Power Input Kit for Mini Bus Bar
364565-B21
HP Modular Distribution Unit 40 Amp (NA/JPN)
252663-D75
HP Modular Distribution Unit 40 Amp (Int'l)
252663-B34
HP Modular Distribution Unit 32 Amp (Int'l)
252662 -B33
HP Modular Distribution Unit 24 Amp (NA/JPN)
NOTE: The Modular Distribution Unit Kits excludes the extension bars as they are not required with the HP BladeSystem p-class 1U power enclosure.
252663-D74
HP BladeSystem Power Extension Kit
NOTE: This kit is specifically for HP BladeSystem p-Class customers who want to upgrade their standard blade enclosures to enhanced blade enclosures and would like to install an additional, redundant 3U power enclosure above the blade enclosures rather than below them. The option kit consists of two extension cable assemblies - one for each side (A and B).
381686-B21

Other Options

HP BladeSystem p-Class Diagnostic Station
NOTE: The Diagnostic Station allows access to the blade and the BL p-Class interconnect switch outside of the enclosure. The option provides power and a data interface so that "offline" upgrade and diagnostic functions may be performed.
230743-B21
HP BladeSystem p-Class Power Enclosure Shipping Bracket Option Kit
NOTE: Used to secure one power enclosure in a rack when moving
365044-B21

USB Options

USB 1.44 MB External Diskette Drive (Carbonite)
DC141B
USB Easy Access Keyboard
267146-XX8
USB Easy Access Keyboard (Carbonite)
DC168B#
USB 2-Button Optical Mouse (Carbonite)
DC172B
USB Optical Scroll Mouse (Carbonite)
DD441B
256MB HP Drive Key II (USB 2.0)
PH657A
 
 
USB Easy Access Keyboard (Carbonite/Silver)
Country Key Code
 
Dash #
Description
Dash#
Description
A2M
ICELAND
ABT
HE
AB0
TAWA
ABU
UK
AB1
KOR
ABV
ARA
AB2
PRC
ABX
FIN
AB6
FRA
ABY
DEN
AB7
GRK
ABZ
ITL
AB8
TURK
AC0
BEL
AB9
PORT
AC4
BRZ
ABA
US
ACB
RUSS
ABB
EURO
AKB
CZE
ABC
FCAN
AKC
HUNG
ABD
GR
AKD
POL
ABE
SP
AKL
THAI
ABF
FR
AKN
BHCSY
ABH
NL
AKR
SLOV
ABJ
Japan
ARK
ICELAND
ABM
LA
B15
KAZ
ABN
NOR
UUZ
SWISS
ABS
SW

HP Rack 5000 Series
(Graphite Metallic)

HP 5642 Rack - Unassembled
358254-B21

Rack Options for Rack 5000 Series

Stabilizer Kit for 5642 Rack (Graphite Carbon)
NOTE: The stabilizing kit is used to prevent rack from tipping over.
374493-B21
Baying Kit for 5642 Rack (Graphite Carbon)
NOTE: The baying kit is used to join two or more HP 5642 racks.
374499-B21

Rack 10000 Series
(Graphite Metallic)

Rack, HP Infrastructure 42U (HV)
379005-001
Rack, HP Infrastructure 42U (LV)
379006-001
HP Rack 10842 (42U) - Pallet
257415-B21
HP Rack 10842 (42U) - Shock Pallet
257415-B22
HP S10614 (14U) Rack Cabinet - Shock Pallet
292302-B22
HP Rack 10647 (47U) Cabinet - Pallet
245160-B21
HP Rack 10647 (47U) Cabinet - Crated
245160-B23
HP Rack 10642 (42U) Cabinet - Pallet
245161-B21
HP Rack 10642 (42U) Cabinet - Shock Pallet
245161-B22
HP Rack 10642 (42U) Cabinet - Crated
245161-B23
HP Rack 10636 (36U) Cabinet - Pallet
245162-B21
HP Rack 10636 (36U) Cabinet - Shock Pallet
245162-B22
HP Rack 10636 (36U) Cabinet - Crate
245162-B23
HP Rack 10622 (22U) Cabinet - Pallet
245163-B21
HP Rack 10622 (22U) Cabinet - Shock Pallet
245163-B22
HP Rack 10622 (22U) Cabinet - Crated
245163-B23
NOTE: -B21 (pallet) used to ship empty racks shipped on a truck
-B22 (shock pallet) used to ship racks with equipment installed (by custom systems, VARs and Channels)
-B23 (crated) used for air shipments of empty racks
Not all HP equipment is qualified to be shipped in the Rack 10000 series.
NOTE: Please see the Rack 10000 QuickSpecs for Technical Specifications such as height, width, depth, weight, and color:
http://h18000.www1.hp.com/products/quickspecs/10995_div/10995_div.html
(Worldwide)
http://h18000.www1.hp.com/products/quickspecs/10995_na/10995_na.html
(North America)
NOTE: For additional information regarding Rack Cabinets, please see the following URL: http://h18000.www1.hp.com/products/servers/proliantstorage/rack-options/index.html

Rack Options for HP Rack 10000 Series

HP Light kit for 10000 series rack
361589-B21
HP Plinth kit for 10000 series rack
251960-B21
42U Side Panel - Graphite Metallic
246099-B21
36U Side Panel - Graphite Metallic
246102-B21
47U Side Panel - Graphite Metallic
255486-B21