contents
 Overview      Standard Features      Systems      Options      TechSpecs line.gif (50 bytes)

Overview

Compaq AlphaServer TS20/TS40
 
1.
CPU Fan Assembly
7.
Operator control panel
2.
PCI card cage
8.
Optional hard disk drive bay
3.
I/O port module
9.
Floppy drive
4.
PCI access cover
10.
Optional tape drive bay (3.5") only
5.
PCI card-cage fan assembly
11.
System card cage
6.
CD-ROM drive
12.
Top Cover

At A Glance
  • Compaq AlphaServer TS20/40 Systems include:
  • Alpha 21264 68/833-MHz CPU with 8-MB L2 Dual Data Rate Cache
  • 14 64-bit PCI I/O expansion slots
  • 512-MB, 1-GB, 2-GB, or 4-GB memory options
  • 1.44-MB diskette drive
  • 600-MB 40X IDE CD-ROM drive
  • Two 9-pin serial ports
  • One 25-pin parallel port
  • RMC dedicated serial port, 6-pin MMJ connector
  • Dual USB ports
  • Keyboard and mouse port
  • Power supply
  • AC (auto sensing)
    -48VDC (normal) or -32 to -72VDC for full range
  • U.S. English keyboard with North America orders
  • 3-button mouse
  • Integral remote system management console
  • Customer documentation
  • Tru64™ UNIX™ or OpenVMS Factory Installed Software
  • 90-day software warranty
  • Protected by Compaq Services, including three-year hardware warranty, on-site with 5 x 9 next business day response
contents
 Overview      Standard Features      Systems      Options      TechSpecs line.gif (50 bytes)

Standard Features

Processor Alpha 21264 68/833-MHz CPU

Cache Memory 8-MB L2 Dual Data Rate Backup Cache

Upgradability Supports additional processors and upgrades of memory and hard drives

Memory Minimum 512 MB
Maximum 16 GB (16 DIMM slots) – AlphaServer TS20
32 GB (32 DIMM slots) – AlphaServer TS40

Network Controller Choice of Ethernet controllers

Expansion PCI I/O slots 14 slots (9 primary and 5 secondary; refer to PCI Configuration Guidelines)

Storage Diskette Drive 1.44 MB diskette drive in dedicated slot
CD-ROM 600-MB 40X IDE CD-ROM
Hard Drives Choice of 9.1-GB, 18.2-GB, or 36.4-GB drives

Interfaces Parallel 1 25-pin parallel port
Serial 2 9-pin serial ports
USB Dual USB ports
Keyboard 1
Mouse 1
Remote systems management 1 dedicated remote systems management port

Graphics Optional

Form Factor Rackmount (Standard or NEBS certified cabinet)

Power Supply Rackmount (Standard or NEBS certified cabinet)

Manageability Compaq Insight Manager

OS Support AlphaServer TS20/40 Tru64 UNIX systems include pre-installed software, Base license, Unlimited User license, Server Extension license, Internet Express, iPlanet Directory Server, iPlanet Enterprise Server, and Compaq Secure Web Server
  AlphaServer TS20/40 OpenVMS systems include pre-installed software, Base license with System Manager license and Enterprise Integration Server License Package for OpenVMS V3.1
  Minimum OS support - Tru64 UNIX V5.1A or Open VMS V7.1-2

Service and Support Protected by Compaq Services including a Three-year on-site hardware warranty with next business day response. Software warranty is a 90-day telephone advisory. Training, consulting, network integration, software support, comprehensive system maintenance and guaranteed uptime services are also available for customers requiring higher levels of service and support.

PCI Configuration Guidelines
  • Physical slots 1 through 5 support only PCI33 Type 0 single-function PCI adapter cards that use a single PCI functional interrupt line.
  • Physical slots 1 through 5 do not suport PCI33 Type 1 multifunction graphics adapters, multiport Ethernet adapters, etc.
  • MEMORY CHANNEL (CCMAB-AA) PCI adapters are ONLY supported installed within physical slots 6-14.
  • IPCON-AA PCI adapter (See input # 7) in physical slot 1 or 5, while a SS7 card is concurrenly installed in physical slot 5 or 1, respectively.
contents
 Overview      Standard Features      Systems      Options      TechSpecs line.gif (50 bytes)

Systems

Step 1 – Select system

AlphaServer TS20/40 systems require the mandatory selection of the following items:
  • Disk drive cage or StorageWorks shelf (see Step 5)
    - Disk drive cage requires Ultra2 SCSI LVD (3X-KZPCA-AA)
    - StorageWorks shelf requires UltraSCSI adapter and SCSI cable (see Step 10)
  • System disk drive (Step 5)
  • Ethernet adapter (Step 7)
  • Chassis Rackmount Kit (see Step 8) - each server includes dress bezel and two power cords
  • Non-North American systems require country-specific keyboard (see Step 16); North American systems include U.S. English keyboard
  • Software media and documentation for first system onsite
NOTE: Bold face part numbers indicate NEBS qualified. For system integration of options with 6-3 part numbers, contact CustomSystems. Option part numbers identified with the notation "U.S./Canada orders"and "Other country orders"refers specifically to the country where the order originates, and indicates the valid and orderable part numbers in the respective geographies.
 

AlphaServer TS20 Systems

TS20

OS

CPU

PCI I/O Slots

Memory/Cache

Order No.

AC Tru64 UNIX 833 MHz 14 512 MB/8 MB DA-T56RA-CA
AC Tru64 UNIX 833 MHz 14 1 GB/8 MB DA-T56RA-DA
AC Tru64 UNIX 833 MHz 14 2 GB/8 MB DA-T56RA-EA
DC Tru64 UNIX 833 MHz 14 512 MB/8 MB DA-T56RB-CA
DC Tru64 UNIX 833 MHz 14 1 GB/8 MB DA-T56RB-DA
DC Tru64 UNIX 833 MHz 14 2 GB/8 MB DA-T56RB-EA
 
AC OpenVMS 833 MHz 14 512 MB/8 MB DY-T56RA-CA
AC OpenVMS 833 MHz 14 1 GB/8 MB DY-T56RA-DA
AC OpenVMS 833 MHz 14 2 GB/8 MB DY-T56RA-EA
DC OpenVMS 833 MHz 14 512 MB/8 MB DY-T56RB-CA
DC OpenVMS 833 MHz 14 1 GB/8 MB DY-T56RB-DA
DC OpenVMS 833 MHz 14 2 GB/8 MB DY-T56RB-EA
 

AlphaServer TS40 Systems

TS40 OS CPU PCI I/O Slots Memory/Cache Order No.
AC Tru64 UNIX 833 MHz 14 512 MB/8 MB DA-T64CA-CA
AC Tru64 UNIX 833 MHz 14 1 GB/8 MB DA-T64CA-DA
AC Tru64 UNIX 833 MHz 14 2 GB/8 MB DA-T64CA-EA
AC Tru64 UNIX 833 MHz 14 4 GB/8 MB DA-T64CA-FA
DC Tru64 UNIX 833 MHz 14 512 MB/8 MB DA-T64CB-CA
DC Tru64 UNIX 833 MHz 14 1 GB/8 MB DA-T64CB-DA
DC Tru64 UNIX 833 MHz 14 2 GB/8 MB DA-T64CB-EA
DC Tru64 UNIX 833 MHz 14 4 GB/8 MB DA-T64CB-FA
 
AC OpenVMS 833 MHz 14 512 MB/8 MB DY-T64CA-CA
AC OpenVMS 833 MHz 14 1 GB/8 MB DY-T64CA-DA
AC OpenVMS 833 MHz 14 2 GB/8 MB DY-T64CA-EA
AC OpenVMS 833 MHz 14 4 GB/8 MB DY-T64CA-FA
DC OpenVMS 833 MHz 14 512 MB/8 MB DY-T64CB-CA
DC OpenVMS 833 MHz 14 1 GB/8 MB DY-T64CB-DA
DC OpenVMS 833 MHz 14 2 GB/8 MB DY-T64CB-EA
DC OpenVMS 833 MHz 14 4 GB/8 MB DY-T64CB-FA
contents
 Overview      Standard Features      Systems      Options      TechSpecs line.gif (50 bytes)

Options

Step 2 - Additional CPU Modules - Optional


  • AlphaServer TS20 includes one CPU, one additional CPU is supported
  • AlphaServer TS40 includes one CPU, three additional CPUs are supported
 
 

 

  SMP upgrade, includes one 68/833-MHz CPU with 8-MB cache and Tru64 UNIX SMP license
KN610-CB
  SMP upgrade, includes one 68/833-MHz CPU with 8-MB cache and OpenVMS SMP license
KN610-CC

 

Step 3 - Memory - Optional


  • Systems include one memory option
  • TS20 systems supports four memory options (total of 16 DIMMs)
  • TS40 systems support eight memory options (total of 32 DIMMs)
  • Memory performance considerations: Interleaved operations reduce the average latency and increase the memory throughput over non-interleaved operations. With one memory option (4 DIMMs) installed, memory interleaving will not occur. With two identical memory options (8 DIMMs) installed, memory read-write operations are two-way interleaved. With four identical memory options (16 DIMMs) installed, memory read-write operations are four-way interleaved, maximizing memory throughput.

 

  512-MB memory option (4 x 128-MB DIMMs)
MS610-CA
  1-GB memory option (4 x 256-MB DIMMs)
MS610-DA
  2-GB memory option (4 x 512-MB DIMMs)
MS610-EA
  4-GB memory option (4 x 1024-MB DIMMs)
MS610-FA

 

Step 4 - Additional Power Supplies - Required for redundancy


  • Power supply included with system provides support for full system
  • Second power supply provides full redundancy
  • Rack kit include two internal power cords regardless of the number of power supplies
  AlphaServer TS20/40 950W 120/240VAC power supply
3X-H7820-AA
  AlphaServer TS20/40 950W –48VDC power supply
3X-H7820-AB

 

Step 5 - Disk Drive Cage or StorageWorks Shelf - Mandatory


  • AlphaServer TS20/40 enclosure supports one 2-bay disk drive cage
  • The number of Universal 42xx/43xx StorageWorks shelves or BA36R StorageWorks shelves dependd upon the selected cabinet.

Step 5a - Disk Drive Cage - Requires selection of system disk drive


  Two-bay disk drive cage with cable for use with 1.0² universal drives – requires mandatory selection of one Ultra2 SCSI adapter (3X-KZPCA-AA)
BA610-2D
NOTE: See AlphaServer TS20/40 Configuration Chart for Storage Adapters in Step 10. Bold face option part numbers indicate NEBS qualified.  

System Disk Drives
(Supported in Disk Drive Cage)
9.1-GB Ultra3 SCSI 10,000 rpm 1.0" Universal disk drive
3R-A0584-AA
9.1-GB Ultra3 SCSI 15,000 rpm 1.0" Universal disk drive
3R-A1542-AA
18.2-GB Ultra3 SCSI 10,000 rpm 1.0" Universal disk drive
3R-A0585-AA
18.2-GB Ultra3 SCSI 15,000 rpm 1.0" Universal disk drive
3R-A1543-AA
36.4-GB Ultra3 SCSI 10,000 rpm 1.0" Universal disk drive
3R-A0919-AA
36.4-GB Ultra3 SCSI 15,000 rpm 1.0" Universal disk drive
3R-A3079-AA
72.8-GB Ultra3 SCSI 10,000 rpm 1.0" Universal disk drive
3R-A3050-AA

Step 5b - StorageWorks Model 4314R and Model 4354R Universal Drive Shelves


StorageWorks Model 4314R Shelves
StorageWorks Model 4314R and 4354R Ultra2 SCSI (LVD) single-bus and split-bus Universal drive shelves; refer to Compaq StorageWorks Enclosure 4300 Family QuickSpecs when configuring shelves. When selecting a DS-SSL13-Rx split-bus shelf, order two 3X-KZPCA-AA adapters with BN38C-05 cables. Model 43xx shelves are compatible with Wide Ultra2 (LVD) adapters only. Note that the depth of a DS-SL13R-xx shelf does not allow front and rear mounting (Universal shelves require onsite installation).
  StorageWorks Model 4314R Ultra3 SCSI (LVD) single-bus Universal drive rackmount shelf, includes one power supply, U.S. (190209-001)
DS-SL13R-AA
  StorageWorks Model 4314R Ultra3 SCSI (LVD) single-bus Universal drive rackmount shelf, includes one power supply, Japan
190209-291
(U.S./Canada orders)
   
DS-SL13R-AJ
(Other country orders)
  StorageWorks Model 4314R Ultra3 SCSI (LVD) single-bus, -48VDC, rackmount shelf, includes two redundant power supplies, dress bezel and two DC power cords
3X-SL13R-TA

StorageWorks Model 4354R Shelves StorageWorks Model 4354R Ultra3 SCSI (LVD) single-bus Universal drive rackmount shelf, includes two redundant power supplies, U.S. (190211-001)
DS-SL13R-BA
  StorageWorks Model 4354R Ultra3 SCSI (LVD) split-bus Universal drive rackmount shelf, includes two redundant power supplies, Japan
190211-291
(U.S./
Canada orders)
   
DS-SL13R-BJ
(Other country orders)
  StorageWorks Model 4354R Ultra3 SCSI (LVD) split-bus, -48VDC, rackmount shelf, includes two redundant power supplies, dress bezel and two DC power cords
3X-SL13R-TB

Additional Power Supplies Additional power supply for single-bus Universal shelf, U.S.
212980-B21
(U.S./Canada orders)
   
DS-SE2UP-AA
(Other country orders)
  Additional power supply for single-bus Universal shelf, International
119826-B31
(U.S./Canada orders)
   
DS-SE2UP-AI
(Other country orders)
  NOTE: Model 4314R shelf with DS-KZPCC-AC adapter does not support a disk drive in last slot. Bold face part numbers indicate NEBS qualified.

System Disk Drives
(Supported in Model 4314Rand Model 4354R Universal Drive Shelves)
9.1-GB Ultra3 SCSI 10,000 rpm 1.0" Universal disk drive
3R-A0584-AA
9.1-GB Ultra3 SCSI 15,000 rpm 1.0" Universal disk drive
3R-A1542-AA
18.2-GB Ultra3 SCSI 10,000 rpm 1.0" Universal disk drive
3R-A0585-AA
18.2-GB Ultra3 SCSI 15,000 rpm 1.0" Universal disk drive
3R-A1543-AA
36.4-GB Ultra3 SCSI 10,000 rpm 1.0" Universal disk drive
3R-A0919-AA
36.4-GB Ultra3 SCSI 15,000 rpm 1.0" Universal disk drive
3R-A3079-AA
  72.8-GB Ultra3 SCSI 10,000 rpm 1.0" Universal disk drive
3R-A3050-AA

StorageWorks Model 4314T Standalone Enclosures Model 4314T Ultra3 SCSI, Single-bus Tower Enclosure, U.S.
190210-001
(U.S./Canada orders)
   
DS-SL13T-AA
(Other country orders)
  Model 4314T Ultra3 SCSI, Single-bus Tower Enclosure, International
(190210-B31
(U.S./Canada orders)
   
DS-SL13T-AB
(Other country orders)
  Model 4314T Ultra3 SCSI, Single-bus Tower Enclosure, Japan
190210-291
(U.S./Canada orders)
   
DS-SL13T-AJ
(Other country orders)

Step 5c – StorageWorks BA36R Shelf - Requires selection of UltraSCSI adapter and SCSI cable (Step 10) and system disk drive
 
  • StorageWorks Shelf supports seven 3.5 x 1.6 hard disk drives; with addition of redundant power supply, only six drives are supported
  • StorageWorks shelf kits are mounted back-to-back in cabinets
 
  StorageWorks UltraSCSI single-bus shelf kit
BA36R-RC
  StorageWorks UltraSCSI split-bus shelf kit
BA36R-RD
  3-meter SCSI cable
BN37A-03

System Disk Drives
(Supported in StorageWorks BA36R Shelf)
9.1-GB Ultra2 SCSI 7,200 rpm disk drive
DS-RZ1DA-VW
9.1-GB Ultra3 SCSI 10,000 rpm disk drive
DS-RZ1DD-VW
18.2-GB Ultra2 SCSI 7,200 rpm disk drive
DS-RZ1EA-VW
18.2-GB Ultra3 SCSI 10,000 rpm disk drive
DS-RZ1ED-VW
36.4-GB Ultra3 SCSI 10,000 rpm disk drive
DS-RZ1FC-VW

 

Step 6 - Internal Removable Media - Optional


  • System supports three internal removable devices
  • System includes 1.44-MB diskette drive
  • System includes 5.25 "half-height 600-MB 40X IDE CD-ROM drive
  • Removable media slot provide support for one 3.50"AIT, or one 3.50² DAT tape drive media device
  3.50" 20/40-GB 4 mm DAT Ultra2 (LVD) SCSI tape drive, graphite black; requires Ultra2 (LVD) adapter (3X-KZPCA-AA)
3X-SD15X-AA
  3.50" 50/100-GB 8 mm AIT Ultra2 (LVD) SCSI tape drive, graphite black; requires Ultra2 (LVD) adapter (3X-KZPCA-AA)
3X-SZ15X-AA
  NOTE: Bold face part numbers indicate NEBS qualified. 3.5"AIT and DAT tapes can only be used with AlphaServer TS20/40.  

 

Step 7 - Ethernet Adapters - Mandatory


  • Adapters require a minimum of Tru64 UNIX V5.1A or OpenVMS V7.1-2
  • Each adapter uses one PCI slot
  • See Step 12 for additional networking options
NOTE: Ethernet adapter is not required if KZPCM or 3X-DEPVZ-AA is selected as SCSI adapter for StorageWorks shelf

  Maximum # Supported
 
  Tru64 UNIX OpenVMS
 
PCI 1-port 32-bit 10/100-Mb single-channel UTP FE Ethernet adapter
(Twisted Pair)
4 4
3X-DE600-AA
PCI to dual-port 10/100 UTP Fast Ethernet adapter (supported under Tru64 UNIX V4.0F and TruClusteä r V1.6)
2 4
3X-DE602-AA
PCI single-port MMF add-on daughter card for 3X-DE602-AA (supported under Tru64 UNIX V4.0F and TruCluster V1.6)
2 2
3X-DE602-FA
PCI 4-port 10/100 Mb Ethernet adapter
1 1
DE504-BA
PCI Combo adapter, includes 10/100 Mbps Ethernet adapter, Ultra2 LVD SCSI adapter, and 2D graphics adapter, no support for multi-head graphics requires OpenVMS V7.1-2 with:
DEC-AXPVMS-VMS712_UPDATE-V0300—4.PCSI
DEC-AXPVMS-VMS712_GRAPHICS-V0300—4.PCSI
DEC-AXPVMS-DNVOSIECO06-V0701—4.PCSI is recommended
OpenVMS V7.2-1 requires Tima kit:
DEC-AXPVMS-VMS&@!_UPDATE-V0100--4.PCSI
Requires Tru64 UNIX V4.0F with NHD2; TruCluster V5.1 support restricted to non-shared buses
Tru64 UNIX V5.1 requires Patch Kit 3: T64V51AS0003-20010413.tar
1 1
3X-DEPVZ-AA
Cable for 10BaseT Twisted Pair connection
   
BN25G-xx
3-meter SCSI cable
   
BN37A-03
PCI Gigabit Ethernet adapter, SC connectors, MMF - no boot support
4 4
DEGPA-SA
PCI 10/200/1000 UTP Ethernet adapter; requires minimum version Tru64 UNIX V5.0A, Patch kit 2: T64V50AAS0002-20001004.tar
4 4
DEGPA-TA
SC-SC dual Fibre Optic cable, mm, pp xx = length in meters
   
BN34B-xx

NOTE: Bold face option part numbers indicate NEBS qualified.
 

Step 8 - System Enclosures - Chassis Rackmount Kit


Step 8a - Chassis Rackmount Kit for NEBS or Standard Cabinet (Non-NEBS)
  • Chassis Slide Kit included for each AlphaServer TS20/40 system
  • Each Chassis Rackmount Kit supports one system
 
  Chassis Rackmount Kit for Standard Cabinet
3X-BA61R-SC

 

Chassis Rackmount Kit for NEBS Cabinet
3X-BA61R-NC

 
Step 9 - Cabinets (Standard and NEBS)
NOTE: Contact Compaq CustomSystems for for any cabinet configurations with AlphaServer TS20/40.
  • Cabinet enclosures require selection of the following items:
  • H9A10 (34U) or H9A15 (41) or NEBS cabinet
  • Power Distribution Unit (PDU); One PDU is included in NEBS cabinet
  • Rear cabinet extender based on cabinet height (H9A10 and H9A15)
  • Cabinet front door based on cabinet height (H9A10 and H9A15)
  • Factory integration
  • Ballast kit if only one system is ordered for the H9A15 cabinet
  • Japan only – 240V cabinet required when using universal shelves (For H9A10 and H9A15 cabinet)
  • Installation of one AlphaServer TS20/40 system in an H9A15 cabinet requires the mandatory selection of a ballast kit for H9A10 and H9A15 cabinet)

General Cabinet Description 67-inch cabinet with 56-inchor 32U of usable vertical space, 120V dual-24A controller, each with 10 NEMA 5-15R outlets, input power plug NEMA L5-30P, Americas, Asia Pacific; includes rear door and top fan tray
H9A10-ZB
  79-inch cabinet with 68.25-inch or 39U of usable vertical space, 5-15R outlets, input power plug NEMA L5-30P, Americas, Asia Pacific; includes rear door and top fan tray
H9A15-ZB
  76-inch cabinet with 70-inch or 38U of usable vertical space, 1900 mm x 600 mm x 600 mm seismic electronic enclosure, 19-inch RETMA mounting rails with non-threaded holes; color Carbon Black; includes rear door and one –48V PDU (3X-H7603-AB)
3X-H9705-AB
  70-inch cabinet with 65-inch or 35U of usable vertical space, 1800 mm x 600 mm x 600 mm seismic electronic enclosure, 19-inch RETMA mounting rails with non-threaded holes; color Carbon Black; includes rear door and one –48V PDU (3X-H7603-AB)
3X-H9705-BB

Rear Cabinet Extender - Optional Rear cabinet extender, graphite black, for H9A10-ZB cabinets
H9C10-ZE
Rear cabinet extender, graphite black, for H9A15-ZB cabinets
H9C15-ZE

Front Trim Kit – Required selection of either Front Door Kit or Front Trim Kit Front trim kit, graphite black, for H9A10-ZE cabinet enclosure
H9C10-ZT
Front trim kit, graphite black, for H9A15-ZE cabinet enclosure
H9C15-ZT

Cabinet Front Door - Required selection of either Front Door Kit or Front Trim Kit Front door, graphite black, for H9A10-ZE cabinet enclosure
H9C10-ZF
Front door, graphite black, for H9A15-ZE cabinet enclosure
H9C15-ZF

Factory Integration - Required Factory Integration of systems and storage devices assembled and configured in cabinet enclosure in predefined locations
YT-CSSIT-01

Ballast Kit - Required only if one system is ordered for the H9A15 cabinet Ballast is added to a cabinet at particular locations for specific configurations to meet safety regulations for installation, operation, and service; see Cabinet Configuration Charts.
Two 35 to 40 lb/16 to 18 kg steel plates
H9C10-MC

Power Distribution Unit (PDU) – For standard cabinet PDU, NEMA Input, NEMA Outlets, 120V
H7600-AA
PDU, NEMA Input, NEMA Outlets, 240V
H7600-AB

Power Distribution Unit (PDU) – For NEBS cabinet Two sections, -48V PDU contains two removable modules rated for 120A. 2U configuration for standard 19.0-inch rackmount and convection cooler. The 48VDC input voltage is distributed to eight separate output connectors
3X-H7603-AB

 

Step 10 - Storage Adapters/Controllers


NOTE: Refer to the following chart when configuring adapters, shelves, and disks.

AlphaServer TS20/40 Configuration Chart for Storage Adapters
Adapter
Shelf
Disk Drive
Tru64 UNIX
OpenVMS
 
 
External RAID
 
 
 
DS-SL13R-xx
3R-A3xxx-AA 1.0"Universal
V4.0F – V5.1
 
 
 
Internal RAID
 
 
DS-KZPCC-AC/CE1
BA610-2D (internal RAID)2
3R-A3xxx-AA 1.0" Universal
V5.1/5.1A
 
3X-KZPCA-AA
BA610-2D
DS-SSL14-Rx
DS-SL13R-xx
3X-SL13R-TA
3X-SL13R-TB
3R-A0xxx-AA 1.0" Universal
3R-A1xxx-AA 1.0" Universal
3R-A1xxx-AA 1.0" Universal
3R-A0xxx-AA 1.0" Universal
3R-A0xxx-AA 1.0" Universal
V4.0F to V5.1
V7.2-1
3X-DEPVZ-AA
DS-SL13R-xx
3X-SL13R-TA
3x-SL13R-TB
3R-A1xxx-AA 1.0" Universal
3R-A0xxx-AA 1.0" Universal
3R-A0xxx-AA 1.0" Universal
V4.0F with NHD2
V7.2-1
KZPCM-DA
BA36R-xx
DS-RZ1xx-VW, DS-EZxxx-VW
V4.0F to V5.1
V7.2-1
KZPBA-CA
BA36R-xx
DS-RZ1xx-VW, DS-EZxxx-VW
V4.0F to V5.1
V7.2-1
NOTE: Ethernet adapter is not required if 3X-DEPVZ-AA or KZPCM-DA is selected as SCSI adapter for StorageWorks shelf.
RAID Controllers
Adapters
Shelf
Disk Drive
Tru64 UNIX
OpenVMS
KZPAC-AA/CA/CB
BA36R-xx
DS-RZ1xx-VW
V4.0F to V5.1
V7.2-1
DS-KZPCC-CE/AC
BA36R-xx*
3R-A0xxx-AA 1.0" Universal
3R-A1xxx-AA 1.0" Universal
V4.0F only
-
 
       

NOTE: * = BA36R-xx shelves require DOC2 I/O module, DS-BA35X-FC; order DS-BA35X-FC as an independent option (will not be factory installed).
  1. DS-KZPCC-AC/CE RAID controllers can be used with universal shelves and drives in TS20/40. Configuration rules are restricted to specific CPU and OS versions:
  2. - Tru64 UNIX V5.1 requires Patch Kit 3 (BL17) and Early Release Patch C462.02
    Only BA610-2D cage (with Nile Cards Rev –0B) shipped after 1 October 2001 supports internal RAID. Contact Customer Services to replace Nile Cards shipped in BA610-2D disk card cage prior to 1 October 2001 where internal RAID is required.

  Maximum # Supported  
  Tru64 UNIX OpenVMS  
PCI 2-port PCI to Ultra3, 64-bit LVD2 SCSI adapter, uses one PCI slot; Includes internal 68-pin and external 68-pin HD connectors; requires BN38C-xx cable to connect adapter to Universal shelf; supports shared JBOD using Models 4314R and 4354R Universal shelves; support restricted to EV68 833-MHz systems only and Tru64 UNIX V5.1A as a minimum.
4 -
3X-KZPEA-DB
PCI 3-port PCI to Ultra2, 64-bit, LVD backplane RAID controller with 64-MB cache (uses one PCI slot); requires connection to DS-SSL14-Rx (maximum seven disks supported per channel) or to DS-SL13R-xx (maximum 14 disks with single channel)
8 -
DS-KZPCC-CE
PCI 1-port PCI to Ultra2, 64-bit, LVD backplane RAID controller with 16-MB cache (uses one PCI slot); requires connection to DS-SSl14Rx (maximum seven disks supported per channel) or to DS-SL13R-xx (maximum 14 disks with single channel)
8 -
DS-KZPCC-AC
PCI to Fibre Channel adapter, 64-bit, single-channel (uses one PCI slot)
NOTE: When used in a switched standalone or cluster environment, a maximum of four adapters is supported. When used in an arbitrated loop non-clustered environment, a maximum of one adapter is supported.
See NOTE See NOTE
DS-KGPSA-CA
(168794-B21)
Fibre Channel cable (BNGBX-xx) xx = 02, 05, 15, 30, 50 meters,
x = 1 (02 m), 2 (05 m), 3 (15 m), 4 (30 m), 5 (50 m)
   
234457-B2x
 
   
 
PCI 1-port Ultra2 (LVD) SCSI adapter, 32-bit, single-channel (uses one PCI slot); includes internal 68-pin and external 68-pin HD connectors; requires BN38C-xx cable to connect adapter to Ultra2 shelf; HSZxx RAID controllers not supported. OpenVMS V7.1-2 requires Tima Kit: DEC-AXPVMS-VMS712_UPDATE-V0300—4.PCSI; Tru64 UNIX V4.0F requires Patch Kit2 BL13: DUV40FAS0002-19991116.tar
6 6
3X-KZPCA-AA
68-pin HD male-to-VHDCI male UltraSCSI cable;
xx = 02, 03, 05, 10, 20, 25 m
   
BN38C-xx
PCI combo adapter – See Step 7
1 1
3X-DEPVZ-AA
PCI 2-port UltraSCSI single-ended adapter and 10/100 Mb Ethernet combo adapter (uses one PCI slot); includes internal 68-pin and 50-pin HD connectors and two external 68-pin VHDCI SCSI connectors, requires BN37A-xx cable to connect to single-ended UltraSCSI shelf
4 4
KZPCM-DA
VHDCI male-to-VHDCI male UltraSCSI cable,
xx = 02, 2E [2.5], 03, 05, 10, 20 m
   
BN37A-xx
 
   
 
PCI 1-port UltraSCSI differential adapter (uses one PCI slot); includes external 68-pin HD connector, requires BN38C-xx cable (2 to 25 m) to connect adapter to differential UltraSCSI shelf or RAID controller
5 5
KZPBA-CB
68-pin HD male-to-VHDCI male UltraSCSI cable;
xx = 02, 03, 05, 10, 20, 25 m
   
BN38C-xx
 
   
 
PCI 1-port UltraSCSI RAID controller with 4-MB cache memory (uses one PCI slot), includes RAID Array 230/Plus Subsystem software and documentation kit; includes VHDCI female connector; tape drives not supported; 18.2-GB disk drives not supported, requires BN37A-xx cable (0.3 to 20 m) to connect to single-ended UltraSCSI shelf
4 4
KZPAC-AA
 
   
 
PCI 3-port UltraSCSI RAID controller with 4-MB cache memory (uses one PCI slot), includes RAID Array 230/Plus Subsystem Software and documentation kit; tape drives not supported; 18.2-GB disk drives not supported; SCSI cable required for each active port; requires BN37X-xx cable (.3 to 20 m) to connect to single-ended UltraSCSI shelf, and BN31K-0E for external third port connection
4 4
KZPAC-CA
Same as KZPAC-CA with 8-MB cache memory
4 4
KZPAC-CB
Cache battery backup for KZPAC controller
   
KZPSC-UB
VHDCI male-to-VHDCI male UltraSCSI cable;
xx = 02, 2E [2.5], 03, 05, 10, 20, 25 m
NOTE: Manufacturing may substitute BN37A-02 cable for specific cabinet configurations.
   
BN37A-xx
SCSI cable/bulkhead assembly kit, supports one third-port connection from KZPAC-CA/CB, allows external connection of one third port
   
BN31K-0E
SCSI cable/bulkhead assembly kit, supports two third-port connections from KZPAC-CA/CB, allows external connection of two third ports
   
KZPAC-SB
       
PCI CI adapter for OpenVMS systems only; requires two PCI slots and CI cable for each adapter
- 2
CIPCA-BA
CI cable
   
BNCIA-xx
   
PCI DSSI controller for OpenVMS systems only; requires HSDxx controller to connect directly to StorageWorks shelf; requires BC29S-xx cable
- 4
KFPSA-AA
6' DSSI cable for connection to HSD10 installed in BA36R pedestal shelf
   
BC29S-06
9' DSSI cable for connection to HSD10 installed in BA36R cabinet shelf
   
BC29S-09

 

Step 11 - Storage Devices - Optional


UltraSCSI Configuration Rules
  • UltraSCSI configurations require UltraSCSI components (controllers, adapters, shelves, disks, and cables)
  • UltraSCSI adapters and RAID controllers support UltraSCSI disks at UltraSCSI speeds in UltraSCSI top gun blue shelves (DS-BA356-xx)
  • UltraSCSI and Fast10 drives can be mixed in DS-BA356 top gun blue UltraSCSI shelf; UltraSCSI adapter negotiates maximum transfer speed of drives
 

UltraSCSI StorageWorks Pedestals
  • UltraSCSI top gun blue pedestals provide support for UltraSCSI disk drives; pedestals are available in single-bus or split-bus configurations and include a personality module and 180W power supply
  • UltraSCSI shelf supports: seven 3.5" hard disk drives, or one 5.25" device and four 3.5" hard disk drives, or two 5.25" devices and one 3.5" hard disk drive
  • Installation of redundant power supply reduces number of 3.5" drive slots by one
 
UltraSCSI single-ended pedestal, single-bus personality module, 180W power supply
DS-BA356-KF
UltraSCSI single-ended pedestal, split-bus personality module, 180W power supply
DS-BA356-KG
UltraSCSI pedestal, single-channel differential personality module, 180W power supply
DS-BA356-KH
180W power supply, includes 120V North American and 240V IEC power cord
DS-BA35X-HH

Tape Drives  

AIT Tape Drives 35/70-GB 8 mm AIT LVD tabletop tape drive, North America; requires 3X-KZPCA-AA LVD adapter
216885-001
35/70-GB 8 mm AIT LVD tabletop tape drive, International; requires 3X-KZPCA-AA LVD adapter
216885-B31
35/70-GB 8 mm AIT LVD tabletop tape drive, Japan; requires 3X-KZPCA-AA LVD adapter
216885-291
35/70-GB 8 mm AIT SCSI tabletop tape drive with 120V North American power cord; requires 3X-KZPCA-AA or KZPBA-CA SCSI adapter
388507-001
35/70-GB 8 mm AIT SCSI tabletop tape drive, International; requires 3X-KZPCA-AA or KZPBA-CA SCSI adapter
388507-B31
50/100-GB 8 mm AIT SCSI tabletop tape drive with 120V North American power cord; requires 3X-KZPCA-AA Wide Ultra2 (LVD) adapter
157767-001
50/100-GB 8 mm AIT SCSI tabletop tape drive, International; requires 3X-KZPCA-AA Wide Ultra2 (LVD) adapter
157767-B31
35/70-GB AIT hot plug LVD Universal tape drive, uses two slots in BA610-2D or 43xxx shelves
3R-A2396-AA
50/100-GB AIT hot plug LVD Universal tape drive, uses two slots in BA610-2D or 43xxx shelves
3R-A2779-AA

AIT Tape Libraries SSL2020 AIT library with one AIT 50-GB drive and 20 slots, rackmount, requires
3X-KZPCA-AA
175196-B21
SSL2020 AIT library with two AIT 50-GB drives and 20 slots, rackmunt, requires
3X-KZPCA-AA
175196-B22
Tabletop SSL2020 AIT library with one AIT 50-GB drive and 20 slots requires
3X-KZPCA-AA LVD adapter
175196-B21
Tabletop SSl2020 AIT library with two AIT 50-GB drives and 20 slots, requires
3X-KZPCA-AA LVD adapter
175196-B22

DAT Tape Drives 12/24-GB 4 mm DAT narrow single-ended tabletop SCSI tape drive with 120V North American power cord; requires BN31W-xx SCSI cable and KZPBA-CA or KZPCM-DA adapter
DS-TLZ10-DB
20/40-GB 4 mm DAT Wide Ultra2 (LVD) tabletop SCSI tape drive with 120V North American power cord; requires 3X-KZPCA-AA Wide Ultra2 (LVD) adapter
157770-001
20/40-GB 4 mm DAT Wide Ultra2 (LVD) tabletop SCSI tape drive, International; requires
3X-KZPCA-AA Wide Ultra2 (LVD) adapter
157770-B31
20/40-GB DAT auto loader external, North America
166505-001
20/40-GB DAT auto loader external, International; requires BN31W-xx SCSI cable and KZPBA-CA or KZPCM-DA adapter
166505-B31
20/40-GB DAT auto loader external, Japan
166505-291
20/40-GB DAT DDS4 hot plug LVD Universal tape drive, uses two slots in BA610-2D or 43xxx shelves
3R-A2780-AA

DLT Tape Drives 35/70-GB DLT single-ended tabletop tape drive, requires BN21K-xx SCSI cable and KZPBA-CA or KZPCM-DA adapter
DS-TZ89N-TA
Tabletop TL881 DLT mini-library with one DLT4000 tape drive; requires HVD KZPBA-CB adapter and SCSI cable
128667-B21
Tabletop TL881 DLT mini-library with two DLT4000 tape drives; requires HVD KZPBA-CB adapter and SCSI cable
128667-B22
Tabletop TL891 DLT mini-library with one TZ89N tape drive; requires HVD KZPBA-CB adapter and SCSI cable
120875-B21
Tabletop TL891 DLT mini-library with two TZ89N tape drives; requires HVD KZPBA-CB adapter and SCSI cable
120875-B22
Tabletop DLT8000 40/80-GB DLT external tape drive; requires 3X-KZPCA-AA LVD adapter
146197-B21
Tabletop DLT8000 40/80-GB DLT external tape drive, Japan; requires 3X-KZPCA-AA LVD adapter
146197-291

Removable Media Devices for StorageWorks Shelves  

AIT Tape Drives 35/70-GB 8 mm AIT SCSI tape drive in 3.5" StorageWorks carrier (BA36R or BA356 shelves)
DS-AIT35-VW
SSL2020 AIT library with one AIT 50-GB drive and 20 slots, rackmount, LVD (Universal shelves)
175196-B21
SSL2020 AIT library with two AIT 50-GB drives and 20 slots, rackmount, LVD (Universal shelves)
175196-B22

DAT Tape Drives 12/24-GB 4 mm DAT narrow SCSI tape drive in StorageWorks carrier (BA36R or BA356 shelves)
DS-TLZ10-VA

DLT Tape Drives 40/80-GB DLT8000 tape drive in StorageWorks carrier (BA36R or BA356 shelves)
DS-TZ90N-VW
20/40-GB DLT single-ended tape drive in StorageWorks carrier (BA36R or BA356 shelves)
TZ88N-VA
35/70-GB DLT single-ended tape drive in StorageWorks carrier (BA36R or BA356 shelves)
DS-TZ89N-VW
DLT mini-library expansion unit with bar code reader, 16 cartridges, wide differential SCSI robotic controller with 68-pin HD female SCSI connector, universal mounting rails (Metric/RETMA)
DS-TL890-NE

DLT Tape Libraries MSL5026DLX or MSL5026Sl, DLT/SDL tabletop library, 0 drives; all MSL 5026 libraries are supported with 3X-DEPVZ-AA and 3X-KZPCA-AA adapters
231838-B21
MSL5026DLX, DLT tabletop library with one 40/80-GB DLT tape drive, LVD
231821-B21
MSL5026DLX, DLT tabletop library with two 40/80-GB DLT tape drive, LVD
231821-B22
MSL5026DLX or MSL5026SL, DLT/SDLT rackmount library, 0 drives
231979-B21
MSL5026DLX, DLT rackmount library with one 40/80-GB DLT tape drives, LVD
231891-B21
MSL5026DLX, DLT rackmount library with two 40/80-GB DLT tape drives, LVD
231891-B22
MSL5026SL, SDLT tabletop library with one 110/220-GB SDLT tape drive, LVD
231822-B21
MSL5026SL, SDLT tabletop library with two 110/220-GB SDLT tape drive, LVD
231822-B22
MSL5026SL, SDLT rackmount library with one 110/220-GB DLT tape drives, LVD
231892-B21
MSL5026SL, SDLT rackmount library with two 110/220-GB DLT tape drives, LVD
2311892-B22
ESL198 DLX Enterprise tape libraries with two 40/80-GB tape drives (161265-B24/-B25/-B26/-B27/-28 for 8, 10, 12, 14, or 16 tape drives); requires KZPBA-CB
194993-B22
TL891DLX DLT tabletop library with one DLT tape drive, LVD
157300-B21
TL891DLX DLT tabletop library with two DLT tape drive, LVD
157300-B22
TL891DLX DLT rackmount library with one DLT tape drive, LVD
157305-B21
TL891DLX DLT rackmount library with two DLT tape drive, LVD
157305-B22
Rackmount TL881 DLT mini-library with one DLT4000 tape drive; requires KZPBA-CB adapter
128668-B21
Rackmount TL881 DLT mini-library with on DLT4000 tape drive; requires KZPBA-CB adapter
128668-B22

BA370 Rackmount Enclosure
  • Mandatory rear cabinet extender ordered for systems installed in M-series cabinets (H9A10 and H9A15) allows two BA370 enclosures to be installed front to back in cabinet
 
  • Host adapter, RAID Array controller, ACS firmware, cache battery, cables, platform-specific Solutions Software Kit, and disk drives must be ordered separately
 
BA370 front mount rackmount enclosure with five 180W power supplies, includes RETMA rackmount kit; first BA370 enclosure must be front mounted in cabinet, 20U height
2T-BA370-AS
BA370 rear mount rackmount enclosure with five 180W power supplies, includes RETMA rackmount kit; second BA370 enclosure must be rear mounted in cabinet, 20U height
2T-BA370-AR

External Storage Solutions/Controllers Modular Array 8000 Fibre Channel RAID storage solution, 60 Hz; includes one HSG80 controller with 256-MB cache, one M2200 controller shelf, three dual-bus disk shelves, two I/O ports, two power supplies
175992-B21
DS-SWXEB-CA
Modular Array 8000 Fibre Channel RAID storage solution, 50 Hz; includes one HSG80 controller with 256-MB cache, one M2200 controller shelf, three dual-bus disk shelves, two I/O ports, two power supplies
175992-B22
DS-SWXEB-CB
Enterprise Modular Array 12000 Fibre Channel RAID storage solution, 60 Hz
175993-B21
Enterprise Modular Array 12000 Fibre Channel RAID storage solution, 50 Hz
175993-B22
NOTE: For Modular Array 8000, and Enterprise Modular Array 12000 configuration and ordering information, see
http://www.compaq.com/products/storageworks/raidstoragesystems.html
NOTE: This Web site is available in English only.
Fibre Channel controller (HSG80), includes 64-MB cache; each HSG80 requires 128697-B21 HSG80 ACS V8.4F software kit for RAID Array and Enterprise Storage Array solutions
380671-B21
Fibre Channel controller (HSG80), includes 256-MB cache; each HSG80 requires 128697-B21 HSG80 ACS V8.4F software kit for RAID Array and Enterprise Storage Array solutions
380672-B21
UltraSCSI controller (HSZ80), includes 64-MB cache; requires 400569-001 for Tru64 UNIX or 400571-001 for OpenVMS for RAID Array and Enterprise Storage Array solutions
400564-B21
UltraSCSI controller (HSZ80), includes 256-MB cache; requires 400569-001 for Tru64 UNIX or 400571-001 for OpenVMS for RAID Array and Enterprise Storage Array solutions
400565-B21

RA3000 RAID Array
  • RAID Array 3000 (HSZ22) storage array is supported on AlphaServer TS20/40 systems (Tru64 UNIX V4.0F, V5.0A or higher and OpenVMS V7.x); supports KZPBA-CB adapter, minimum console V5.8
 
 

RA8000, ESA12000 Ultra and RA8000, ESA12000 Fibre Channel
  • RAID Array 8000 and ESA 12000 (HSZ80) storage arrays are supported on AlphaServer TS20/40 systems
  • RAID Array 8000 FC and ESA 12000 FC (HSG80) storage arrays are supported on AlphaServer TS20/40 systems
  • For ordering information see:
    http://www.compaq.com/products/storageworks/raidstoragesystems.html
    NOTE: This Web site is available in English only.
 

 

Step 12 - Networking Adapters/Controllers - Optional


  • Adapters require a minimum of Tru64 UNIX V4.0F or OpenVMS V7.1-2
  • Each adapter/controller uses one PCI slot
  • See Step 7 for supported Ethernet adapters
NOTE: Ethernet adapter is not required if 3X-DEPVZ-AA or KZPCM is selected as SCSI adapter for StorageWorks shelf.


  Maximum # Supported  
  Tru64 UNIX OpenVMS  
PCI FDDI adapter, single attachment station (SAS), multi-mode fiber (MMF), SC connector
4 4
3X-DEFPA-AC
PCI FDDI adapter, DAS, MMF, SC connector
4 4
3X-DEFPA-DC
MIC-SC dual fiber optic cable
   
BN34D-xx
SC-to-SC dual fiber optic cable
   
BN34B-xx
PCI FDDI adapter, DAS, TP-PMD
4 4
3X-DEFPA-MC
PCI FDDI adapter, SAS, TP-PMD, requires BN25H-03
4 4
3X-DEFPA-UC
3-m (9.8¢ ) FDDI cross-over cable
   
BN25H-03
       
PCI 2-port intelligent synchronous controller
OpenVMS systems require V7.1-2 and minimum of X.25 V1.5 with Kits;
-DEC-AXPVMS-WANDD-V0105-1.1.PCSI
-DEC-AXPVMS-X25-V0105-1.1.PCSI
BC33x-xx cable required
4 4
3X-PBXDD-AA
PCI 4-port intelligent synchronous controller
OpenVMS systems require V7.1-2 and minimum of X.25 V1.5 with Kits;
-DEC-AXPVMS-WANDD-V0105-1-1.PCSI
-DEC-AXPVMS-X25-V0105-1-1.PCSI
BC33xx-xx cable required
4 4
3X-PBXDD-AB
       
PCI 4-port asynchronous controller; maximum two PBXDA-Ax per system
(Tru64 UNIX systems require V4.0F)
2 2
PBXDA-AA
PCI 8-port asynchronous controller, cable included; maximum two PBXDA-Ax per system (Tru64 UNIX systems require V4.0F)
2 2
PBXDA-AB
PCI 16-port asynchronous controller, cable included; maximum two PBXDA-Ax per system (Tru64 UNIX systems require V4.0F)
2 2
PBXDA-AC
 
   
 
Asynchronous multi-port MUX expander XEM
   
CXI01-AB
Asynchronous MUX cable converter (RJ45-DB25)
   
CXI01-AC
Asynchronous MUX adapter (RJ45-MJ11), 8 pack
   
CXI01-AF
 
   
 
PCI-to-ATM 155 Mb adapter - Fiber
6 -
3X-DAPBA-FA
PCI-to-ATM 155 Mb adapter - UTP
6 -
3X-DAPBA-UA
PCI-to-ATM 622 Mb adapter - Fiber
4 -
3X-DAPCA-FA

 

Step 13 - MEMORY CHANNEL - Optional


Tru64 UNIX Systems
(V5.0A and later)
  • Each system node in the cluster requires a TruCluster software license
    (QL-6BRAE-AA)
 

OpenVMS Systems
  • OpenVMS V7.1-2 or later and OpenVMS Cluster license (QL-MUZAE-AA) are required
 

Configuring Information
  • Up to two PCI-to-System Area Network adapters (CCMAB-AA) are supported in a single system.
  • For two-node clusters order a CCMAB-AA for each system and one BN39B-04 or BN39B-10 cable; cable connects directly to CCMAB-AA in each system.
  • For three or four system nodes, order one CCMAB-AA adapter, one BN39B-04 or BN39B-10 cable and one CCMHB-AA; make connections from the CCMAB-AA in a system to the CCMHB-AA.
  • CCMHB-AA includes four CCMLB-AA line cards and supports up to four nodes; expansion up to eight system nodes can be achieved by adding up to four CCMLB-AA line cards.
  • If two CCMAB-AAs are configured in each system, a second CCMHB-AA is required for three or more nodes; in two-node clusters, the CCMAB-AAs may be directly connected.
  • If nodes must be separated by a distance longer than standard copper cables allow, the CCMFB option converts the output of the standard CCMAB controller or CCMLB line card to single-mode fiber optic cable. The fiber optic connection may be up to 2,000 meters long between two CCMAB controllers connected in virtual hub mode, or 3,000 meters between a CCMAB controller and a CCMHB hub. (The connection from the CCMHB hub to a second system may also be 3,000 meters.) The CCMFB option requires a second PCI slot in the system from which it draws power only. It is normally connected to the corresponding CCMAB controller with the short BN39B-01 cable. The CCMFB is also used in the CCMHB hub where it occupies a slot normally used by the CCMLB line card, limiting expansion to four radial fiber optic connections.
  • CCMHB-BA hub expansion box provides additional slots for up to eight fiber optic connections. Two standard length single-mode fiber optic cables are available from Compaq (BN34R-10 and BN34R-31); however, users normally provide this fiber optic connection. Fiber optic connectivity is completely transparent to the systems using it and has no performance impact
 

MEMORY CHANNEL Controller/System Area Network Hub PCI-to-System Area Network Controller, maximum two
CCMAB-AA
System Area Network Hub with four line cards; includes BN19P-2E power cord for Canada, Japan, and U.S. - for other regions, order appropriate power cord from the following list:
CCMHB-AA
Hub expansion box with no line cards
CCMHB-BA
Expansion line card for CCMHB hub
CCMLB-AA
1-meter cable for CCMAB and CCMHB
BN39B-01
4-meter cable for CCMAB and CCMHB
BN39B-04
10-meter cable for CCMAB and CCMHB
BN39B-10
Copper-to-single mode fiber optic converter
CCMFB-AA
Rackmount kit for CCMHB hub
3X-BA61R-MC
Power cord for rackmount CCMHB hub
BN35S-02

MEMORY CHANNEL Power Cords Australia, New Zealand
103541-011
(U.S./Canada orders)
 
BN19H-2E
(Other country orders)
Central Europe
BN19C-2E
Denmark
(U.S./Canada orders)
 
BN19K-2E
(Other country orders)
Egypt, India
103541-AR1
(U.S./Canada orders)
 
BN19S-2E
(Other country orders)
Ireland, United Kingdom
BN19A-2E
Israel
BN18L-2E
Italy
103541-461
(U.S./Canada orders)
 
BN35M-02
(Other country orders)
Switzerland
103541-511
(U.S./Canada orders)
 
BN19E-2E
(Other country orders)

 

Step 14 - Graphics Adapters - Optional


  • RAID Configuration Utility is accessible via console port; optional graphics capability is available
  • Select graphics adapter, monitor, and country-specific keyboard for Tru64 UNIX and OpenVMS systems if required
  Maximum # Supported  
  Tru64 UNIX OpenVMS  
3Dlabs Oxygen VX1 32-MB PCI 2D graphics accelerator
1 1
SN-PBXGF-AB
PowerStorm 4D51T advanced 3D graphics accelerator
4 -
SN-PBXGI-AD
PowerStorm 300 3D multi-head graphics accelerator with 15-MB frame buffer memory and 16-MB texture memory; Patch Kit 1, Environmental Patch; V1.4 for multi-head (Kit Rev 4.0)
8 4
SN-PBXGD-AD
PowerStorm 350 3D multi-head graphics accelerator with 30-MB frame buffer memory and 32-MB texture memory; Patch Kit 1, Environmental Patch; V1.4 for multi-head (Kit Rev 4.0)
8 4
SN-PBXGD-AE

 

Step 15 - Monitors - Optional


  • Graphics monitors other than those listed can be used if compatible with SVGA graphics ordered with system
  • Video extension cable required if monitor is located more than 1 meter from server
  • Monitors will ship with, but not be integrated with systems.

Carbon/Silver Monitors

 

V570 15-inch (13.8-inch viewable image size) multiple-scan color monitor, VGA to 1024 x 768 @85 Hz, 0.28 mm DP, MPRII/Energy Star Compliant, Northern Hemisphere with NA power cord, VGA cable
3R-A3383-AA
228113-001
Same as above with Euro-power cord, TCO99
3R-A3384-AA
228113-021
Same as above, APD, no power cord, MPRII
3R-A3385-AA
228113-B22
Same as above, PRC with power cord, CCIB
3R-A3386-AA
228113-AA1
Same as above, Southern Hemisphere, with Australia/New Zealand power cord
3R-A3387-AA
228113-011
Same as above, Equatorial, for Latin America with NA power cord
3R-A3704-AA
228113-B29
P720 17-inch (16-inch viewable image size) auto-scanning color monitor, Diamondtron NF, 0.25 mm aperture grille pitch, VGA to 1280 x 1024 @85 Hz, MPRII/TCO 99/Energy Star Compliant, Northern Hemisphere with NA power cord, VGA cable
3R-A3388-AA
244373-001
Same as above, with Euro-power cord
3R-A3389-AA
244373-021
Same as above, APD, no power cord
3R-A3390-AA
244373-B24
Same as above, PRC with power cord, CCIB
3R-A3391-AA
244373-AA1
Same as above, Southern Hemisphere, with Australia/New Zealand power cord
3R-A3392-AA
244373-011
P920 19-inch (18-inch viewable image size) auto-scanning color monitor, Diamondtron NF, 0.24 mm aperture grille pitch, VGA to 1600 x 1200 @85 Hz, MPRII/TCO 99/Energy Star Compliant, Northern Hemisphere with NA power cord, VGA cable
3R-A3393-AA
244375-001
Same as above, with Euro power cord
3R-A3394-AA
244375-021
Same as above, PRC with power cord, CCIB
3R-A3396-AA
244375-AA1
Same as above, Southern Hemisphere, 0.25 to 0.27 mm aperture grille pitch, with Australia/New Zealand power cord
3R-A3397-AA
244375-011
P1220 22-inch (20-inch viewable image size) auto-scanning color monitor, Diamondtron NF, 0.24 mm aperture grille pitch, VGA to 1792 x 1344 @85Hz, dual video input, USB Hub, MPRII/TCO 99/Energy Star Compliant, Northern Hemisphere with NA power cord, VGA cable
3R-A3398-AA
244374-001
Same as above, with Euro power cord
3R-A3399-AA
244374-021
Same as above, APD, no power cord
3R-A3400-AA
244374-B24
Same as above, PRC with power cord, CCIB
3R-A3401-AA
244374-AA1
Same as above, Southern Hemisphere, with Australia/New Zealand power cord
3R-A3402-AA
244374-011

Carbon/Silver Flat Panel Monitors TFT8030, 18.1-inch (18.0-inch viewable image size) TFT flat panel monitor, 0.28 mm pixel pitch, 1280 x 1024 @75 Hz, multi-mode support, MPRII/TCO99/Energy Star compliant, six video input connectors (two VGA, two DVI-I, one S-video, and one C-video), NA power cord, VGA and DVI-I cables
3R-A3511-AA
234362-001
TFT5030, 15.1-inch (15.0-inch viewable image size) TFT flat panel monitor, 0.30 mm pixel pitch, 1024 x 768 @75 Hz, multi-mode support, MPRII/TCO99/Energy Star compliant, two video input connectors (one VGA and one DVI-I), NA power cord, VGA and DVI-I cables
3R-A3353-AA
228134-001

Video Extension Cable 6 foot/1.8-meter video extension cable- optional
BN39C-02

Monitor Power Cords North America
BN26J-1K
Australia, New Zealand, 2.5-meter
103541-011
(U.S./Canada orders)
 
BN19H-2E
(Other country orders)
Central Europe, 2.5-meter
BN19C-2E
Denmark, 2.5-meter
103541-481
(U.S./Canada orders)
 
BN19K-2E
(Other country orders)
Egypt, India, South Africa, 2.5-meter
103541-AR1
(U.S./Canada orders)
 
BN19S-2E
(Other country orders)
Israel, 2.5-meter
BN18L-2E
Italy, 2.5-meter
103541-461
(U.S./Canada orders)
 
BN35M-02
(Other country orders)
Japan, 2.5-meter, Dentori approved
3X-BN46F-02
Switzerland, 2.5-meter
103541-511
(U.S./Canada orders)
 
(BN19E-2E
(Other country orders)
UK, Ireland, 2.5-meter
BN19A-2E

 

Step 16 - Keyboards, Power Cords, Documentation


Step 16a - Keyboards - Required for all non-North American systems


  • Select a keyboard and mouse
  • All keyboards listed may not be available in all geographies
  • Select an opal OpenVMS keyboard and opal mouse for use with VT5xx text terminals.
  • Systems ordered in North America include U.S. English keyboard; selection of country-specific keyboard is mandatory for all non-North American systems
 
Opal
Carbon
Keyboard/Language
OpenVMS
Tru64 UNIX
OpenVMS
U.S./English keyboard
LK461-A2
3R-LKQ48-AA
3X-LK462-A2
Arabic keyboard
-
3R-LKQ48-BR
-
Belgian keyboard
LK461-AB
3R-LKQ48-AB
3X-LK462-AB
BHCSY keyboard
-
3R-LKQ48-AX
-
Canadian/English keyboard
LK461-AQ
-
3X-LK462-AQ
Canadian/French keyboard
LK461-AC
3R-LKQ48-AC
3X-LK462-AC
Cyrillic keyboard (Russian)
LK461-BT
3R-LKQ48-BT
3X-LK462-BT
Czech keyboard
LK461-BV
3R-LKQ48-BV
3X-LK462-BV
Danish keyboard
LK461-AD
3R-LKQ48-AD
3X-LK462-AD
Dutch keyboard
LK461-AH
3R-LKQ48-AH
3X-LK462-AH
Finnish keyboard
LK461-AF
3R-LKQ48-AF
3X-LK462-AF
French keyboard
LK461-AP
3R-LKQ48-AP
3X-LK462-AP
German keyboard
LK461-AG
3R-LKQ48-AG
3X-LK462-AG
Greek keyboard
LK461-BH
3R-LKQ48-BH
3X-LK462-BH
Hebrew keyboard
LK461-AT
3R-LKQ48-AT
3X-LK462-AT
Hungarian keyboard
LK461-BQ
3R-LKQ48-BQ
3X-LK462-BQ
International keyboard
-
3R-LKQ48-BA
-
Italian keyboard
LK461-AI
3R-LKQ48-AI
3X-LK462-AI
Japanese keyboard
-
3R-LKQ48-AJ
-
Korean keyboard
-
3R-LKQ48-BK
-
Latin-American keyboard
-
3R-LKQ48-AR
-
Norwegian keyboard
LK461-AN
3R-LKQ48-AN
3X-LK462-AN
Polish keyboard
LK461-BP
3R-LKQ48-BP
3X-LK462-BP
Portuguese keyboard
LK461-AV
3R-LKQ48-AV
3X-LK462-AV
Romanian keyboard
LK461-BL
-
3X-LK462-BL
Simplified Chinese keyboard
-
3R-LKQ48-CV
-
Slovak keyboard
LK461-CZ
3R-LKQ48-CZ
3X-LK462-CZ
Spanish keyboard
LK461-AS
3R-LKQ48-AS
3X-LK462-AS
Swedish keyboard
LK461-AM
3R-LKQ48-AM
3X-LK462-AM
Swiss/French keyboard
LK461-AK
3R-LKQ48-AK
3X-LK462-AK
Swiss/German keyboard
LK461-AL
-
3X-LK462-AL
Traditional Chinese keyboard
-
3R-LKQ48-BI
-
Thai keyboard
-
3R-LKQ48-CB
-
Turkish keyboard
LK461-BU
3R-LKQ48-BU
3X-LK462-BU
Turkish/French keyboard
LK461-BW
-
3X-LK462-BW
UK keyboard
-
3R-LKQ48-AE
-
Yugoslavian keyboard
LK461-BY
-
3X-LK462-BY

Mouse 3-button mouse – opal
SN-PBQWS-WA
3-button mouse – carbon
3R-A3480-AA

Keyboard or Mouse Extension Cable 6 foot/1.8 meter keyboard or mouse extension cable; to extend both keyboard and mouse order two cables
3X-BC34A-06

Step 16b - Power Cords

Power Cords
  • Each system ordered in North America includes two, 120V or –48VDC power cords; selection of country specific power cords is mandatory for all non-North American systems. Please contact product manager for additional information.
  • Additional power supply do not requires additional cord
 

Step 16c - Documentation

  Additional AlphaServer TS20/40 System Information Kit (print), Owners Guide, User Interface Guide, and Release Notes
EK-TS42R-IN

 
Step 17 - Console Terminal - Optional

 
  • Any terminal can be used as a console device
  • Third-party console devices require an EIA-232 25-pin DSUB connector
  VT510 video terminal; requires keyboard, H8575-x adapter, and BC16E-x cable
VT510-xx
  Console cable, female connector (25-pin passive adapter)
H8575-A
  Console cable, male connector (adapter with EOS, ESD, 25 POS D-SUB)
H8575-D

 
Step 18 - Software - Required selection of media and documentation for first system on site

  • Software Processor Code = E

Tru64 UNIX
  • AlphaServer TS20/40 Tru64 UNIX systems include Unlimited User license, Server Extension license, Internet Express, iPlanet Directory Server, iPlanet Enterprise Server, and Compaq Secure Web Server
 

When using Tru64 UNIX V5.0A or later Tru64 UNIX media and online documentation on CD-ROM
QA-6ADAA-H8
Tru64 UNIX full hard copy documentation
QA-6ADAA-GZ
StorageWorks Software Package, with licenses for Logical Storage Manager and AdvFS Utilities
QB-5RXAE-AA
TruCluster Server License
QL-6BRAE-AA
Advanced Server for Tru64 UNIX, 25 client concurrent use license
QL-5U29M-3D
Advanced Server for Tru64 UNIX, 50 client concurrent use license
QL-5U29M-3E
Advanced Server for Tru64 UNIX, 100 client concurrent use license
QL-5U29M-3F
Advanced Server for Tru64 UNIX, 250 client concurrent use license
QL-5U29M-3G
Advanced Server for Tru64 UNIX, 500 client concurrent use license
QL-5U29M-3H
Layered products media and documentation for Tru64 UNIX on CD-ROM
QA-054AA-H8
DECnet/OSI extended function license for Tru64 UNIX
QL-MTJAE-AA
DECnet/OSI end-system license for Tru64 UNIX
QL-MTKAE-AA
Open3D for Tru64 UNIX on CD-ROM, includes graphics drivers
QA-OAFAA-H8

OpenVMS
  • AlphaServer TS20/40 OpenVMS systems include Base license with System Manager license and Compaq Enterprise Integration Server License Package for OpenVMS Revision V3.0A
  • Compaq Enterprise Integration Package includes licenses for TCP/IP Services for OpenVMS, DECwindows Motif for OpenVMS Alpha, DECprint Supervisor for OpenVMS Alpha Plus, DECprint Supervisor for OpenVMS Open, DECnet-Plus for OpenVMS Alpha End System, Archive/Backup System for OpenVMS Management Tools, Archive/Backup Agent for Microsoft® Windows®NT™ , OpenVMS Disk Services for Windows NT, Office Server for OpenVMS, PATHWORKS 32, PATHWORKS V6 for OpenVMS – Advanced Server, and DIGITAL Office Server Client Access License
  • OpenVMS Concurrent Use licenses provide the right to interactively use the operating system by the specified number of concurrent users on a designated OpenVMS system. OpenVMS Concurrent Use licenses can be moved from one system to another at user discretion and can be shared in a mixed OpenVMS VAX and OpenVMS Alpha cluster.
  • OpenVMS Traditional Unlimited Use license is system specific and can only be used on one system at a time. It cannot be shared between systems or in an OpenVMS VAX or OpenVMS Alpha Cluster.
  Concurrent Use 1-user license
QL-MT3AA-3B
  Concurrent Use 2-user license
QL-MT3AA-3C
  Concurrent Use 4-user license
QL-MT3AA-3D
  Concurrent Use 8-user license
QL-MT3AA-3E
  Concurrent Use 16-user license
QL-MT3AA-3F
  Concurrent Use 32-user license
QL-MT3AA-3G
  Concurrent Use 64-user license
QL-MT3AA-3H
  Concurrent Use 128-user license
QL-MT3AA-3J
  Concurrent Use 256-user license
QL-MT3AA-3K
  Traditional unlimited user license
QL-MT2AE-AA
  OpenVMS V7.1-2 media and online documentation on CD-ROM
QA-MT1AR-H8
  OpenVMS V7.2-1 media and online documentation on CD-ROM
QA-MT1AT-H8
  OpenVMS media and documentation on CD-ROM
QA-MT1AA-H8
  OpenVMS full hard copy documentation
QA-001AA-GZ
  Layered products media and documentation for OpenVMS on CD-ROM, includes Enterprise Integration Server for OpenVMS media and documentation.
QA-03XAA-H8
  DECnet extended function license for OpenVMS
QL-MTGAE-AA
  DECnet end-system to extended function upgrade license for OpenVMS
QL-MTHAE-AA
  OpenVMS Cluster license for Alpha systems
QL-MUZAE-AA
  OpenVMS Volume Shadowing license
QL-2A1AE-AA

 
Step 19 - Service and Support - Optional

Compaq Services provides a wide range of service offerings, which are available as Statement of Work/Customized contracts. Contact you local Services Department for details and pricing. For information on Compaq service options available for AlphaServers and AlphaStations, consult a Compaq Sales Account Manager or visit http://www.compaq.com/services/
NOTE: This Web site is available in English only.
contents
 Overview      Standard Features      Systems      Options      TechSpecs line.gif (50 bytes)

TechSpecs

AlphaServer TS20/40 Physical Specifications

Chassis Weight 130 lb (58.97 kg)
  Length 21.75 in (63.5 cm)
  Width 19.0 in (44.45 cm)
  Height 15.75 in (35.56 cm)

AlphaServer TS20/40 AC System Environmental Specifications

Temperature Operating 50° to 104° F (10° to 40° C)
Non-operating –40° to 151° F (–40° to 66° C)
Storage (60 days) –40° to 151° F (–40° to 66° C)
Rate of change 20° F/hr (11° C/hr)
Relative humidity Operating 20% to 80%
Non-operating 20% to 80%
Storage (60 days) 10% to 90%
Rate of change 20%/hr
Maximum wet bulb temperature Operating 82° F (28° C)
Storage (60 days) 115° F (46° C)
Maximum dew point temperature Operating 36° F (2° C)
Heat dissipation Nominal 900 W, 3074 BTU/hr
Maximum 1300 W, 4440 BTU/hr
Airflow and quality Intake location Front
Exhaust location Rear
Particle size N/A
Concentration N/A
Altitude Operating 10,000 ft (3,048 m)
Non-operating (40,000 ft (12,192 m)
Vibration Operating 10 to 500 Hz, 0.1 G peak
Non-operating 5 to 300 Hz, 1.03 G rms

AlphaServer TS20/40 DC System Environmental Specifications

Temperature Operating (continuous) 41° F to 104° F (5 to 40° C)
Operating (short term) 41° F to 131° F (5 to 55° C)
Non-operating –40° to 158° F (–40 to 70° C)
Rate of change 54° F/hr (30° C/hr)
Relative humidity Operating 5° to 90% (noncondensing)
Non-operating 5° to 93%
Maximum wet bulb temperature Operating 89° F (32° C)
Non-operating 102° F (39° C)
Heat dissipation Nominal 900 W, 3074 BTU/hr
Maximum 1300 W, 4440 BTU/hr
Airflow and quality Intake location Front
Exhaust location Rear
Particle size N/A
Concentration N/A
Altitude Operating 10,000 ft (3,048 m)
Non-operating 40,000 ft (12,192 m)

AlphaServer TS20/40 DC Electrical Specifications

Nominal voltage –48 VDC  
Operational voltage range –36 to –72 VDC  
Input current (maximum) 27.1 A at –48 VDC  
Input power 1300 W  

DC Design Operating Temperature Output Power Input Voltage
Output power (104° F to 131° F) 40° to 55° C (short term) 960 W 40 to 72 VDC
  41° F to 104° F (5° to 40° C) 900 W 36 to 40 VDC

AlphaServer TS20/40 AC Electrical Specifications

Nominal voltage (VAC) 100 120 200 to 240
Voltage range (VAC) temporary condition 90 to 100 110 to 128 180 to 250
Power source phase Single Single Single
Nominal frequency (Hz) 50/60 50/60 50/60
Frequency range (Hz) 49 to 51/59 to 61 49 to 51/59 to 61 49 to 51/59 to 61
RMS current
(maximum steady state)
10.7 A 8.9 A 5.4 A
Power Cords (2) 14 ft. 10 in/52 cm IEC 320 C13 to NEMA 5-15 (North America) or IEC320 C13 to IEC 320 C14 (other countries)
Cabinet Power Cords (2) 10 ft 10 in/30 cm 120 V non-removable NEMA L5-30P or 200-240 V non-removable IEC 309

AC Design Operating Temperature Output Power Input Voltage
Output power 41° F to 104° F
(5° to 40° C)
960 W 100 to 270 VAC
  41° F to 104° F
(5° to 40° C)
820 W 90 to 100 Vac

AlphaServer TS20/40 Acoustic Data

Acoustics — Declared Values per ISO 9296 and ISO 7779

  LWAd, B LpAm, dBA (bystander positions)
Idle 6.6 48
  Operating 6.6 48

AlphaServer TS20/40 Regulatory Approvals

Agency approvals UL: Listed to UL1950 (3rd edition) ULC
FCC: Part 15.B Class A
CE: EN55022, EN50082
VCCI Class II ITE
BCIQ: CISPR22, CNS13438
c-Tick: CISPR22, AS/NZS 3548
  Reviewed to AS/NZ 3260:1993 Australian/New Zealand Standard
EN 60950/A4: 1997 European Norm
IEC 950 (2nd edition, 4th amend)
  Other approvals/certification
(DC version)
Bellcore NEBS GR-63-CORE
Bellcore NEBS GR-1089-CORE11
Bellcore SR-3580

© Copyright 2003 Hewlett-Packard Development Company, L.P.
The information contained herein is subject to change without notice.
UNIX is a registered trademark or trademark of The Open Group in the U.S. and/or other countries. The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial errors or omissions contained herein.


   DA-11038 - World Wide - Version 4 - October 1, 2003 --- Retired on May 25, 2004