| Processor | Alpha 21264C 68/1250-MHz CPU | ||
|
|
|||
| Cache Memory | 8-MB (1 GHz) or 16-MB (1.25 GHz) L2 Dual Data Rate Backup Cache | ||
|
|
|||
| Upgradability | Supports additional processors and upgrades of memory and hard drives | |
|
|
||
| Memory | Minimum | 1 GB AlphaServer ES45 |
| Maximum | 16 GB (16 DIMM slots) - Model
1B 32 GB (32 DIMM slots) - Model 2B or Model 3B |
|
|
|
||
| Network Controller | Choice of Ethernet controllers |
|
|
|
| Expansion | PCI I/O slots | Up to ten PCI slots See PCI Configuration Guidelines | |
|
|
|||
| Storage | Diskette Drive | 1.44-MB diskette drive in dedicated slot | |
| DVD-ROM Drive | 16X DVD-ROM drive | ||
| Hard Drives | Choice of 36.4-GB, 72.8-GB, 146-GB or 300-GB drives | ||
|
|
|||
| Interfaces | Parallel | One 25-pin parallel port | |
| Serial | Two 9-pin serial ports | ||
| Keyboard | One port | ||
| Mouse | One port | ||
| Remote Management Console port (RMC) | One 6-pin MMJ dedicated port | ||
| SCSI connections | Knockouts for two additional 68-pin external SCSI connections | ||
|
|
|||
| Graphics | Optional |
|
|
|
| Form Factor | Tower | Up to 12 Universal disk drives |
| Pedestal | Up to 40 Universal disk drives | |
| Rackmount | Up to 152 Universal disk drives | |
|
|
||
| Power Supply | One auto-sensing power supply, hot swappable, N+1, power factor corrected |
|
|
|
| Manageability | Insight Manager |
|
|
|
| OS Support | AlphaServer ES45 Tru64 UNIX systems include pre-installed software, Base license, Unlimited User license, Server Extension license, Internet Express, and Secure Web Server |
|
AlphaServer ES45 OpenVMS systems include pre-installed software, Base license with System Manager license and Enterprise Integration Server License Package for OpenVMS |
|
| Minimum OS support - Tru64 UNIX V5.1A or OpenVMS V7.3 | |
|
|
|
| Service and Support | Protected by HP Services including a one-year on-site hardware warranty with next business day response. Training, consulting, network integration, software support, comprehensive system maintenance and guaranteed uptime services are also available for customers requiring higher levels of service and support. |
|
AlphaServer ES45 systems are available in the following models or configurations:
When configuring an AlphaServer ES45 system, refer to the following chart that summarizes the features of each model as well as the differences between each model. |
|
|
|
|
|
AlphaServer ES45 Model Summary
|
Model 1B (1.25 GHz)
|
Model 2B (1.25 GHz)
|
Model 3B (1.25 GHz)
|
|
I/O Slots
|
7
|
10
|
10
|
|
- 33-MHz PCI Slots
|
2
|
4
|
8
|
|
- 66-MHz PCI Slots
|
4
|
6
|
2
|
|
- 4X AGP Slots
|
1
|
0
|
0
|
|
Power Supplies (Minimum/Maximum)
|
1-3
|
1-3
|
1-3
|
|
Power Supply (DC Watts) One included maximum
three power supplies per system
|
3X-H7514-AA
|
3X-H7514-AA
|
3X-H7514-AA
|
|
1080 Watts
|
1080 Watts
|
1080 Watts
|
|
|
Memory (Minimum/Maximum)
|
1 GB 16 GB
|
1 GB 32 GB
|
1 GB 32 GB
|
|
Memory Option (4-GB Option)
|
MS620-DB
|
MS620-DB
|
MS620-DB
|
|
Higher Power DIMM
|
Higher Power DIMM
|
Higher Power DIMM
|
|
|
Memory Channel I/O Space (CCMAB-AA)
See Memory Channel Step 9 |
128K
|
128K
|
512K or 128K
|
| NOTE: Minimum firmware for 1.25-GHz systems is V6.2-8, minimum SROM firmware is V2.22-F. Firmware files are available at: http://ftp.digital.com/pub/Digital/Alpha/firmware/interim/es45/v6.2C/ | |
|
|
| PCI Configuration Guidelines |
|
PCI Module Descriptions:
|
|
|
|
AlphaServer ES45 systems provide four I/O hoses, each is configured differently as illustrated in the following charts for Models 1B, 2B, and 3B. |
|
|
|
| AlphaServer ES45 PCI bus and slot specification for Model 1B follows: | |||
| PCI Slot | PCI Bus Speed | Signal Voltage | PCI Hose Number |
| 1 | 33 MHz | 5.0 V | 0 |
| 2 | 33 MHz | 5.0 V | 0 |
| 3 | AGP 4X | 1.5 V | 2 |
| 4 | 66 MHz | 3.3 V | 3 |
| 5 | 66 MHz | 3.3 V | 3 |
| 6 | - | - | - |
| 7 | 66 MHz | 3.3 V | 1 |
| 8 | 66 MHz | 3.3 V | 1 |
| AlphaServer ES45 PCI bus and slot specification for Model 2B follows: | |||
| PCI Slot | PCI Bus Speed | Signal Voltage | PCI Hose Number |
| 1 | 66 MHz | 3.3 V | 2 |
| 2 | 66 MHz | 3.3 V | 2 |
| 3 | 33 MHz | 5.0 V | 0 |
| 4 | 66 MHz | 3.3 V | 3 |
| 5 | 66 MHz | 3.3 V | 3 |
| 6 | 33 MHz | 5.0 V | 0 |
| 7 | 66 MHz | 3.3 V | 1 |
| 8 | 66 MHz | 3.3 V | 1 |
| 9 | 33 MHz | 5.0 V | 0 |
| 10 | 33 MHz | 5.0 V | 0 |
| AlphaServer ES45 PCI bus and slot specification for Model 3B follows: | |||
| PCI Slot | PCI Bus Speed | Signal Voltage | PCI Hose Number |
| 1 | 33 MHz | 5.0 V | 2 |
| 2 | 33 MHz | 5.0 V | 2 |
| 3 | 33 MHz | 5.0 V | 0 |
| 4 | 66 MHz | 3.3 V | 3 |
| 5 | 66 MHz | 3.3 V | 3 |
| 6 | 33 MHz | 5.0 V | 0 |
| 7 | 33 MHz | 5.0 V | 1 |
| 8 | 33 MHz | 5.0 V | 1 |
| 9 | 33 MHz | 5.0 V | 0 |
| 10 | 33 MHz | 5.0 V | 0 |
|
|
Systems
| Step 1 Select system |
|
|
| AlphaServer ES45 Model 1B, Model 2B, and Model 3B Systems require the mandatory selection of the following items. AlphaServer ES45 Base Systems require the selection of a minimum of 1-GB memory in addition to the following mandatory items. |
|
| NOTE: Only 2-5-2 part numbers are factory integrated. |
|
|
|
AlphaServer ES45 Systems (1250 MHz) |
|||||
| ES45 |
OS |
CPU |
PCI I/O Slots |
Memory/Cache |
Order Number |
| Model 1B | Tru64 UNIX | 1250 MHz | 6 PCI, 1 AGP 4X | 1 GB/16 MB | DA-66EBA-BA |
| Model 1B | Tru64 UNIX | 1250 MHz | 6 PCI, 1 AGP 4X | 2 GB/16 MB | DA-66EBA-CA |
| Model 1B | Tru64 UNIX | 1250 MHz | 6 PCI, 1 AGP 4X | 4 GB/16 MB | DA-66EBA-DA |
| Model 1B | OpenVMS | 1250 MHz | 6 PCI, 1 AGP 4X | 1 GB/16 MB | DY-66EBA-BA |
| Model 1B | OpenVMS | 1250 MHz | 6 PCI, 1 AGP 4X | 2 GB/16 MB | DY-66EBA-CA |
| Model 1B | OpenVMS | 1250 MHz | 6 PCI, 1 AGP 4X | 4 GB/16 MB | DY-66EBA-DA |
| Model 2B | Tru64 UNIX | 1250 MHz | 10 PCI | 1 GB/16 MB | DA-68EBA-BA |
| Model 2B | Tru64 UNIX | 1250 MHz | 10 PCI | 2 GB/16 MB | DA-68EBA-CA |
| Model 2B | Tru64 UNIX | 1250 MHz | 10 PCI | 4 GB/16 MB | DA-68EBA-DA |
| Model 2B | OpenVMS | 1250 MHz | 10 PCI | 1 GB/16 MB | DY-68EBA-BA |
| Model 2B | OpenVMS | 1250 MHz | 10 PCI | 2 GB/16 MB | DY-68EBA-CA |
| Model 2B | OpenVMS | 1250 MHz | 10 PCI | 4 GB/16 MB | DY-68EBA-DA |
| Model 3B | Tru64 UNIX | 1250 MHz | 10 PCI | 1 GB/16 MB | DA-67EBA-BA |
| Model 3B | Tru64 UNIX | 1250 MHz | 10 PCI | 2 GB/16 MB | DA-67EBA-CA |
| Model 3B | Tru64 UNIX | 1250 MHz | 10 PCI | 4 GB/16 MB | DA-67EBA-DA |
| Model 3B | OpenVMS | 1250 MHz | 10 PCI | 1 GB/16 MB | DY-67EBA-BA |
| Model 3B | OpenVMS | 1250 MHz | 10 PCI | 2 GB/16 MB | DY-67EBA-CA |
| Model 3B | OpenVMS | 1250 MHz | 10 PCI | 4 GB/16 MB | DY-67EBA-DA |
|
AlphaServer ES45 Base Systems (1250 MHz) |
||||
| NOTE: Selection of a minimum of 1-GB memory is mandatory for AlphaServer ES45 Base systems. | ||||
| ES45 |
OS |
CPU |
PCI I/O Slots |
Order Number |
| Model 1B | Tru64 UNIX | 1250 MHz/16 MB | 6 PCI, 1 AGP 4X | DA-66EBA-AA |
| Model 1B | OpenVMS | 1250 MHz/16 MB | 6 PCI, 1 AGP 4X | DY-66EBA-AA |
| Model 2B | Tru64 UNIX | 1250 MHz/16 MB | 10 PCI | DA-68EBA-AA |
| Model 2B | OpenVMS | 1250 MHz/16 MB | 10 PCI | DY-68EBA-AA |
| Model 3B | Tru64 UNIX | 1250 MHz/16 MB | 10 PCI | DA-67EBA-AA |
| Model 3B | OpenVMS | 1250 MHz/16 MB | 10 PCI | DY-67EBA-AA |
Step 2 - Additional CPU Modules - Optional |
||
|
|
||
|
||
| SMP upgrade, includes one 68/1000-MHz CPU with 8-MB cache and Tru64 UNIX SMP license | KN610-DB | |
| SMP upgrade, includes one 68/1000-MHz CPU with 8-MB cache and OpenVMS SMP license | KN610-DC | |
| SMP upgrade, includes one 68/1250-MHz CPU with 16-MB cache and Tru64 UNIX SMP license | KN610-EB | |
| SMP upgrade, includes one 68/1250-MHz CPU with 16-MB cache and OpenVMS SMP license | KN610-EC | |
| NOTE: Minimum firmware for 1.25-GHz systems is V6.2-8, minimum SROM firmware is V2.22-F. Firmware files are available at: http://ftp.digital.com/pub/Digital/Alpha/firmware/interim/es45/v6.2C/ | ||
| NOTE: Existing AlphaServer ES45 1-GHz Model 2 (xx-68DAA-xx) customers who upgrade to 1.25-GHz CPUs should continue to follow Model 2 configuration guidelines. The following options are required: H7906-A9 power supply and MS620-AA, MS620-BA, and MS620-CA memory options. Do not order 3X-H7514-AA power supplies or MS5620-DB memory options. | ||
|
|
||
Step 3 - Memory - Optional |
||
|
|
||
|
||
| 512-MB memory option (4 x 128-MB DIMMs) | MS620-AA | |
| 1-GB memory option (4 x 256-MB DIMMs) | MS620-BA | |
| 2-GB memory option (4 x 512-MB DIMMs) | MS620-CA | |
| 4-GB memory option (4 x 1024-MB DIMMs) | MS620-DB | |
| NOTE: Do not order MS620-DB memory option for installation in ES45 1-GHz Model 2 (xx-68DAA-xx) system. MS620-DB memory option can only be installed in (xx-6xDBA-xx) and (xx-6xEBA-xx) systems. | ||
|
Memory performance considerations:
|
||
| The following examples illustrate different ways of configuring a 4-GB system. Case C yields the best performance and is the recommended method for configuring memory on an AlphaServer ES45 system. | ||
|
|
||
| ES45 System (one memory option included) |
Add-on Memory Options | Total Memory | Total DIMMs | Performance |
| Case A - DA-68EBA-DA (MS620-DB) | None | 4-GB | 4 | Good |
| Case B - DA-68EBA-CA (MS620-CA) | MS620-CA | 4-GB | 8 | Better |
| Case C - DA-68EBA-BA (MS620-BA) | MS620-BA + MS620-BA + MS620-BA | 4-GB | 16 | Best* |
| * NOTE: Operating system and application dependent. Up to an 18% performance enhancement has been measured in Case C over Case A. |
|
|
Options
| Step 4 - Additional Power Supply - Optional | ||
|
|
||
| One Power Supply |
Standard with Model 1B, 2B, and 3B systems; provides system support for:
|
|
| Two Power Supplies |
Optional Provides system support for:
|
|
| Third Power Supply | Optional - Provides (N+1) power redundancy system support for two power supply configuration | |
|
||
| ES45 1080 W power supply; order
for Models 1B, 2B, and 3B (1-GHz) and Models 1B, 2B, and 3B (1.25-GHz) systems
only; do not order for Model 2 (xx-68DAA-xx) systems. |
3X-H7514-AA | |
| ES45 720 W power supply; order for Model 2 (1-GHz xx-68DAA-xx) systems only. | H7906-A9 | |
|
|
||
Step 5 - Disk Drive Cage, Universal Drive Shelf, or Universal Disk Drive - Mandatory |
|
|
|
|
|
| Step 5a - Disk Drive Cage - Requires selection of system disk drive | ||
|
|
||
| Disk drive cage with storage cable accommodates up to six internal 1-inch Universal disk drives Requires mandatory selection of a Storage Adapter in the system. Requires an internal Ultra2 SCSI or Ultra3 SCSI channel per disk drive cage. Maximum of two storage cages in system. | BA610-6D | |
| NOTE: See ES45 Configuration Chart for Storage Adapters in Step 10. | ||
|
|
||
| Universal Disk Drives (Supported in Disk Drive Cage and Universal StorageWorks Shelves) |
36.4-GB Ultra320 SCSI 15,000 rpm 1-inch Universal disk drive | 3R-A3849-AA |
| 72.8-GB Ultra320 SCSI 10,000 rpm 1-inch Universal disk drive | 3R-A3839-AA | |
| 72.8-GB Ultra320 SCSI 15,000 rpm 1-inch Universal disk drive | 3R-A3851-AA | |
| 146-GB Ultra320 SCSI 10,000 rpm 1-inch Universal disk drive | 3R-A3841-AA | |
| 146-GB Ultra320 SCSI 15,000 rpm 1-inch Universal disk drive | 3R-A4945-AA | |
| 300-GB Ultra320 SCSI 10,000 rpm 1-inch Universal disk drive | 3R-A4952-AA | |
| 300-GB Ultra320 SCSI 15,000 rpm 1-inch Universal disk drive | 3R-A6726-AA | |
|
|
||
| Step 5b - StorageWorks Model 4314R and Model 4354R Universal Drive Shelves | ||
|
|
||
|
||
| StorageWorks Model 4314R Ultra3 SCSI (LVD) single-bus Universal drive rackmount shelf, includes one power supply, U.S. | DS-SL13R-AA | |
| StorageWorks Model 4314R Ultra3 SCSI (LVD) single-bus Universal drive rackmount shelf, includes one power supply, Japan | DS-SL13R-AJ | |
| StorageWorks Model 4354R Ultra3 SCSI (LVD) split-bus Universal drive rackmount shelf, includes two redundant power supplies, U.S. | DS-SL13R-BA | |
| StorageWorks Model 4354R Ultra3 SCSI (LVD) split-bus Universal drive rackmount shelf, includes two redundant power supplies, Japan | DS-SL13R-BJ | |
|
|
||
| Step 5c - StorageWorks Modular Storage Array 30 (MSA30) Universal Drive Shelves | ||
|
|
||
|
||
| StorageWorks Modular Smart Array SW4414R Single Bus Ultra320 rackmountable SCSI disk drive, 4-node Storage Enclosure (302969-B21). Includes one 12-foot VHDCI/VHDCI SCSI cable and two IEC-C13 power cords. See Supported Options List for configuration details --http://h18002.www1.hp.com/alphaserver/options/ases45/ases45_options.html | 3R-A4075-AA | |
| StorageWorks Modular Smart Array SW4454R Dual Bus Ultra320 rackmountable SCSI disk drive, 4-node Storage Enclosure (302970-B21). Includes two 12-foot VHDCI/VHDCI SCSI cables and two IEC-C13 power cords. See Supported Options List for configuration details --http://h18002.www1.hp.com/alphaserver/options/ases45/ases45_options.html | 3R-A4076-AA | |
| M-series Rack Rail Kit Option | 3R-A5281AA/ 313877-B21 | |
| NOTE: The 3R-A4075-AA and 3R-A4076-AA enclosures are not supported in a shared-SCSI cluster using the 3X-KZPEA-DB adapter. | ||
|
|
||
Step 6 - System Enclosures - Mandatory selection of Tower, Pedestal, Rack Kit, Power Cords |
||
|
|
||
|
||
|
|
| Step 6a Tower Enclosure | ||
|
|
||
|
||
| 200240V Tower Enclosure | BA61M-CT | |
|
|
||
| Step 6b Pedestal Enclosure | |||
|
|
|||
|
|||
| 200-240V Pedestal Enclosure | BA61P-CB | ||
|
|
|||
| Step 6c Rack Kit for M-Series Cabinet or Series 10000 G2 Rack | ||
|
|
||
|
||
| M-Series |
Rack kit for AlphaServer ES45, includes dress bezel, slides, three internal IEC/IEC power cords, all brackets and hardware for mounting in M-Series cabinets, 200-240V | BA61R-CR |
| Series 10000 | Rack kit for AlphaServer ES45, includes slides, three internal IEC/IEC power cords, all brackets and hardware for mounting in Series 10000 racks | 3X-BA61R-RD |
|
|
||
| Step 6d Power Cords (for Tower/Pedestal Models) | ||
|
|
||
| North America, 200 to 240V, 75-inch Tower | BN18J-1K | |
| North America, 200 to 240V, 108-inch Pedestal | 3X-BN64A-1C | |
| Australia, New Zealand, China, 2.5-meter (8121-0838) | 3R-A6023-AA | |
| Central Europe, 2.5-meter | BN19C-2E | |
| Denmark, 2.5-meter (103541-481) | BN19K-2E | |
| Egypt, India, South Africa, 2.5-meter (103541-AR1) | BN19S-2E | |
| Israel, 2.5-meter | 3R-A6883-AA | |
| Italy, 2.5-meter (103541-461) | BN19M-2E | |
| Japan, 2.5-meter, Dentori approved | 3X-BN46F-02 | |
| Switzerland, 2.5-meter (103541-511) | BN19E-2E | |
| UK, Ireland, 2.5-meter | BN19A-2E | |
|
|
||
Step 7 - Cabinets |
||
|
|
||
| Step 7a - M-Series Cabinets - Optional | ||
|
|
||
NOTE: For more information on M-Series Cabinet Enclosures, see http://www.compaq.com/alphaserver/products/m-series/specs.html |
||
|
|
|
Cabinet Configuration Chart for AlphaServer ES45 (8U)
with 43xx Series StorageWorks Shelves (3U) Supports high-density
configurations
|
||||||
| Cabinet (b) | Front Door or Trim Kit |
Cabinet Depth Extender |
Power Distribution Unit |
ES45 Systems |
43xx/MSA30 Storage Shelves | Unused U Spaces |
| H9A10-ME/-MF | 3X-H9C10-RF or H9C10-ZT |
H9C10-ZE | With second H7609 | 1 | 8 | 1 |
| (34U) | 2 | 5 | 2 | |||
| 3 | 3 | 0 | ||||
| 4 | 0 | 1 | ||||
| H9A15-ME/-MF | 3X-H9C15-RF or H9C15-ZT |
H9C15-ZE | With second H7609 | 1(a) | 10 | 2 |
| (41U) | 2 | 8 | 0 | |||
| 3 | 3 | 7 | ||||
| 4 | 0 | 8 | ||||
| (b) | 3 | 3 or 5 | 1 | |||
| With second H7609 | 4 | 0 or 2 | 2 | |||
| 5 | 0 | 0 | ||||
|
NOTES:
|
||
|
|
| M-Series Cabinets - Specify cabinet selection | 67-inch carbon black cabinet with 59.5-inch or 34U of usable vertical space, 200-240V dual-16A PDU, 16 IEC C13 outlets, two input power plug NEMA L620P, Americas, Asia Pacific; includes rear door. | H9A10-ME |
| 67-inch carbon black cabinet with 59.5-inch or 34U of usable vertical space, 240V dual-16A PDU, 16 IEC C13 outlets, two input power plug IEC 309, 20A, Europe; includes rear door. | H9A10-MF | |
| 79-inch carbon black cabinet with 71.7-inch or 41U of usable vertical space, 200-240V dual-16A PDU, 16 IEC C13 outlets, two input power plug NEMA L620P, Americas, Asia Pacific; includes rear door. | H9A15-ME | |
| 79-inch carbon black cabinet with 71.7-inch or 41U of usable vertical space, 240V dual-16A PDU, 16 IEC C13 outlets, two input power plug IEC 309, 20A, Europe; includes rear door. | H9A15-MF | |
|
|
||
| Rear Cabinet Extender - Mandatory based on cabinet height | Rear cabinet extender for carbon black H9A10 cabinets | H9C10-ZE |
| Rear cabinet extender for carbon black H9A15 cabinets | H9C15-ZE | |
|
|
||
| Front Cabinet Treatment - Mandatory based on cabinet height | Front door for carbon black H9A10 cabinet enclosure | 3X-H9C10-RF |
| Front trim kit for carbon black H9A10 cabinet enclosure | H9C10-ZT | |
| Front door for carbon black H9A15 cabinet enclosure | 3X-H9C15-RF | |
| Front trim kit for carbon black H9A15 cabinet enclosure | H9C15-ZT | |
|
|
||
| Factory Integration - Mandatory | Factory Integration of systems and storage devices assembled and configured in cabinet enclosure in predefined locations | YS-ASCAA-AA |
|
|
||
| Ballast Kit - Mandatory if only one ES45 system drawer is ordered for the H9A15 cabinet |
|
|
| Two 3540 lb (1618 kg) steel plates | H9C10-MC | |
|
|
||
| Power Distribution Unit - Mandatory | Single Phase, Double Power Controller, 16 outlet North America/Japan 240V | 3X-H7609-EB |
| Single Phase, Double Power Controller, 16 outlet, Europe 240V | 3X-H7609-DB | |
|
|
||
| Storage Shelves Supported in M-Series Cabinets - Optional | For supported StorageWorks shelves, see Step 5b. | |
|
|
||
| Step 7b - Rack 10000 G2 Series - Optional | ||
|
|
||
|
The HP Rack 10000 Series were designed to the19-inch RETMA standard.
The Racks accommodate all HP equipment (ProLiant, Alpha Systems, StorageWorks,
UPS, and PDUs) in addition to select third-party equipment. Configuration Guidelines
|
||
|
|
||
| 10000 G2 Series Rack | 10000 G2 Series 42U Rack - mandatory selection of three-phase or two single-phase Power Distribution Units required |
AF004A
|
| Rack Kit - Mandatory for 10000 G2 Series Rack |
Order one for each ES45 System for mounting in 10000 G2 Series Rack |
3X-BA61R-RD
|
| Side Panel Kit - Mandatory
Choice of Side Panel Kit or Baying Kit for 10000 G2 Series Rack |
Order one per 10000 G2 Series Rack |
AF054A
|
| Baying Kit - Mandatory Choice of Side Panel Kit or Baying Kit for 10000 G2 Series Rack |
Used to join two or more Series 10000 G2 Racks |
248931-B21
|
| Power Distribution Units - Mandatory for 10000 G2 Series Rack | ||
| Single-phase PDU | Single-phase PDU for North America/Japan 200-240V 20A input plug NEMA L620P; 16 outlets |
3X-H7609-EB
|
| Single-phase PDU for International, 240V 20A input plug IEC309, 16 outlets |
3X-H7609-DB
|
|
|
|
||
| Step 7c - KVM (Keyboard, Video, Mouse) Switch - Optional | ||
|
|
||
| KVM (Keyboard,
Video, Mouse) Switch - Optional |
The HP Server Console Switch
1 x 8 (8-port) is supported on Alpha Systems using PS/2 mouse and keyboard
with VGA video - this includes support for the PS/2 interface adapter, part
number 262588-B21, required for operation. The switch is supported on systems
running Tru64 UNIX operating system - minimum version V5.1A and the OpenVMS
operating system - minimum version 7.3-2. The KVM is 1U high and can be
installed in the M-Series cabinet or Series 10000 rack. Supports up to eight
servers. |
|
| HP Server 1 x 8-port KVM Console Switch | 336044-B21 | |
| CAT5e Cables | 3 foot (1m) - 4 pack |
263474-B21 |
| 6 foot (2m) - 8 pack | 263474-B22 | |
| 12 foot (4m) - 8 pack |
263474-B23 | |
| 20 foot (6m) - 4 pack |
263474-B24 | |
| 40 foot (12m) - 1 pack | 263474-B25 | |
| Interface Adapters | PS/2 Interface Adapter - 1 pack |
262588-B21 |
| PS/2 Interface Adapter - 8 pack | 262587-B21 | |
| NOTE: Supported graphics cards - ELSA GLoria Synergy (SN-PBXGK-BB), 3Dlabs Oxygen VX1 (SN-PBXGF-AB), and ATI RADEON 7500 (3X-PBXGG-AA) | ||
| For more information,
refer to the Release Notes at: http://h18002.www1.hp.com/alphaserver/download/console_switch_rn.pdf http://h18002.www1.hp.com/alphaserver/download/html/console_switch_rn.html |
||
|
|
||
| Step 8 - Networking Adapters/Controllers Mandatory Ethernet Adapter |
||
|
|
| Step 8a Networking Adapters/Controllers Mandatory | ||
|
|
||
|
||
|
|
| Maximum # Supported | ||||||
| Tru64 UNIX | Open VMS |
PCI Slot | ||||
|
Ethernet 10/100
|
PCI (32/64-bit, 33-MHz to 66-MHz) dual-port 10/100 Ethernet
(UTP/RJ45s) NIC and Base Module. (One 3X-DE602-TR or 3X-DE602-FR optional
add-on daughter card can be combined with this module.)
NOTE: Use BN25G, BN26M, BN24Q, BN28Q twisted pair RJ45 cables. |
4 | 4 | 3.3/ 5 V |
66 MHz |
3X-DE602-BR
|
| Ethernet 10/100/1000 | PCI single-port 10/100/1000
Mbps (Twisted-Pair Copper with RJ45) Gigabit Ethernet; Tru64 UNIX V5.1B/TruCluster
V5.1B supports up to eight nodes and requires: - T64V51BB22AS0002-20030415.tar Requires Early Release Patch to update driver to V1.0.21: T64V51BB22-C0019200-19212-E-20030710.tar http://ftp1.support.compaq.com/public/unix/v5.1b/ t64v51bb1-0003000-16672-e-20030130.README Tru64 UNIX V5.1A/TruCluster V5.1A supports up to eight nodes and requires Early Release Patch: - T64V51AB21-C0127901-19213-E-20030710.tar OpenVMS V7.301 support as a standalone network interface and as a cluster interconnect requires that users download and install the following two ECO Kits: DEC-AXPVMS-VMS731_PCSI_V0100-4.PCSI DEC-AXPVMS-VMS731_LAN_V0600-4.PCSI NOTE: Use BN25G, BN26M, BN24Q, BN28Q twisted pair RJ45 cables. |
8 | 8 | 3.3/ 5 V |
66 MHz |
3X-DEGXA-TR
|
|
|
| Step 8b Networking Adapters/Controllers Optional | ||
|
|
| Maximum # Supported | ||||||
| Tru64 UNIX | Open VMS |
PCI Slot | ||||
|
Ethernet 10/100/1000
|
PCI single-port 1000 Mbps (MMF with duplex-SC) Gigabit Ethernet; Tru64
UNIX V5.1B/TruCluster V5.1B supports up to eight nodes and requires:
- T64V51BB22AS0002-20030415.tar |
8 | 8 | 3.3/ 5 V |
66 MHz |
3X-DEGXA-SR
|
|
Ethernet 10/100
|
Dual-port 10/100 Ethernet (UTP/RJ45) add-on daughter card
for use with the 3X-DE602-BR only. The combined 3X-DE602-BR and 3X-DE602-TR
modules, running at 66MHz, provide four 10/100 (UTP/RJ45s) ports in a
single PCI slot option; allows for a maximum of 16 ports per system.
OpenVMS V7.3 requires Tima Kit: - DEC-AXPVMS-VMS73_LAN-V0100-4.PCSI NOTE: 3X-DE602-TR cannot be used standalone. Use BN25G, BN26M, BN24Q, or BN28Q twisted pair RJ45 cables. |
4 | 4 | 3.3/ 5 V |
66 MHz |
3X-DE602-TR
|
|
Single-port 100 Mbps (MMF/duplex-SC) add-on daughter card
for use with the 3X-DE602-BR. The combined 3X-DE602-BR and 3X-DE602-FR
modules, running at 66 MHz, provide two 10/100 (UTP/RJ45s) and one 100Mbps
(MMF/SC) ports in a single PCI slot option.
NOTE: 3X-DE602-FR cannot be used standalone. Use BN34A or BN34B cables. |
4 | 1 per 3X-DE602- BR |
3.3/ 5 V |
66 MHz |
3X-DE602-FR
|
|
Multi-function Module
|
PCI 32-bit, 33-MHz multi-function (single-port 10/100
Ethernet UTP/RJ45, Ultra2 LVD SCSI, and 2D graphics) adapter. Model 1B
requires installation on PCI Bus 0 in slots 1 or 2; Models 2B and3B require
installation on PCI Bus 0 in slots 3, 6, 9, or 10
NOTE: Tru64 UNIX V5.1A requires Patch Kit 3: T64V51AS0003-20010413.tar. Only one 3X-KZPEA-DB allowed on same PCI bus; no multi-head graphics support; TruCluster support restricted to non-shared SCSI buses only. Use BN25G, BN26M, BN24Q, or BN28Q twisted pair RJ45 cables. |
1 | 1 | 5V | 33 MHz |
3X-DEPVZ-AA
|
|
3X-DEPVZ-AA specific-use 3-meter LVD2 SCSI cable
|
BN37A-03
|
|
Synchronous Communications
|
PCI (32-bit, 33-MHz) to Dual-port Intelligent Synchronous
Communications NIC Requires at least one (maximum two) 3X-BC34x
sync cable listed below.
|
4 | 4 | 3.3/ 5 V |
33 MHz | 3X-PBXDD-AA |
|
PCI (32-bit, 33-MHz) to Quad-port Intelligent Synchronous
Communications NIC Requires at least one (maximum four) 3X-BC34x
sync cable listed below.
|
4 | 4 | 3.3/ 5 V |
33 MHz | 3X-PBXDD-AB |
|
Synchronous-specific Cables
|
V.24/EIA-232 Single-port cable
|
3X-BC34L-06
|
||||
|
V.11/x.21 Single-port cable
|
3X-BC34S-06
|
|||||
|
V.35 Single-port cable
|
3X-BC34T-06
|
|
Asynchronous Communications
|
PCI (32-bit, 33-MHz) to 4-port Async Communications NIC
with DB-25 octopus cable
NOTE: The Tru64 UNIX driver (UNIX Tar File 4001180K.tar) is located at: http://support.digi.com/support/indexes/tru64-xr.html The OpenVMS driver kit (Filename 4001778L.bin) is located at http://support.digi.com/support/drivers/vms/index-async.html |
2 | 2 | 3.3/ 5 V |
33 MHz |
PBXDA-BA
|
|
PCI (32-bit, 33-MHz) to 8-port Async Communications NIC
with DB-25 octopus cables
NOTE: The Tru64 UNIX driver (UNIX Tar File 4001180K.tar) is located at:http://support.digi.com/support/indexes/tru64-xr.html The OpenVMS driver kit (Filename 4001778L.bin) is located at http://support.digi.com/support/drivers/vms/index-async.html |
2 | 2 | 3.3/ 5 V |
33 MHz |
PBXDA-BB
|
|
|
PCI (32-bit, 33-MHz) to 16-port Async Communications Controller
and tabletop 16-port distribution box with RJ45 connectors.
|
2 | 2 | 3.3/ 5 V |
33 MHz |
PBXDA-AC
|
| Step 8c Multi-use Cables | ||
|
|
|
Ethernet, FDDI,
ATM |
Multimode fiber optic (MMF) 62.5/125um duplex cable, with
SC-to-ST connectors
xx = available lengths: (2E, 4E, 01, 03, 10, 20, 30) for 2.4, 4.5, 1, 3, 10, 20, and 30 meters |
BN34A-xx
|
||||||
|
Multimode fiber optic (MMF) 62.5/125um duplex cable, with
SC-to-SC connectors
xx = available lengths: (2E, 4E, 01, 03, 10, 20, 30) for 2.4, 4.5, 1, 3, 10, 20, and 30 meters |
BN34B-xx
|
|||||||
|
Category 5e (4-Unshielded Twisted Pairs / UTP) straight-through
cable with RJ45-to-RJ45 connectors for system to switch, repeater, or
hub connectivity
xx = available lengths: (0B, 0E, 01, 03, 04, 07) for 0.2, 0.5, 1, 3, 4, and 7 meters |
BN25G-xx
|
|||||||
|
Category 5e (4-Twisted Pairs, Screened/ ScTP) straight-through
cable with RJ45-to-RJ45 connectors for system to switch, repeater, or
hub connectivity
xx = available lengths: (0E, 01, 03, 04, 07) for 0.5, 1, 3, 4, and 7 meters |
BN26M-xx
|
|||||||
|
Category 5e (4-Unshielded Twisted Pairs / UTP) Xover cable
with RJ45-to-RJ45 connectors for system to switch, repeater, or hub connectivity
xx = available lengths: (0E, 01, 03, 04, 07) for 0.5, 1, 3, 4, and 7 meters |
BN24Q-xx
|
|||||||
|
Category 5e (4-Twisted Pairs, Screened / ScTP) Xover cable
with RJ45-to-RJ45 connectors for system to switch, repeater, or hub connectivity
xx = available lengths: (0E, 01, 03, 04, 07) for 0.5, 1, 3, 4, and 7 meters |
BN28Q-xx
|
|||||||
|
|
| Step 9 - Memory Channel - Optional | ||
|
|
| Tru64 UNIX Systems (V5.1A) | Each system node in the cluster
requires a TruCluster software license (QL-6BRAE-AA) or TruCluster Plus Software Package (QP-6R9AE-AA) |
|
|
|
||
| OpenVMS Systems | OpenVMS V7.3 and OpenVMS Cluster license (QL-MUZAE-AA) are required | |
|
|
||
| Configuring Information |
|
|
|
|
|
Model 1B
|
Model 2B
|
Model 3B
|
|
128K I/O
|
128K I/O
|
128K I/O
|
|
Use for new or existing clusters; if existing cluster
at 512K, shut down and configure all nodes to 128K
|
Use for new or existing clusters; if existing cluster
at 512K, shut down and configure all nodes to 128K
|
Use for new or existing clusters; if existing cluster
at 512K, shut down and configure all nodes to 128K
|
|
Supports dual-rail, (two)
Memory Channel controllers on single PCI Bus 0 |
Supports dual-rail, (two)
Memory Channel controllers on single PCI Bus 0 |
Supports dual-rail, (two)
Memory Channel controllers on separate PCI Bus (0, 1, or 2) |
|
|
| MEMORY CHANNEL Controller/System Area Network Hub | PCI-to-System Area Network Controller, maximum two - 5V/3.3V | CCMAB-BA |
| System Area Network Hub with four line cards; includes BN19P-2E power cord for Canada, Japan, and U.S. - for other regions, order appropriate power cord from the following list: | CCMHB-AA | |
|
Hub expansion box with no line cards |
CCMHB-BA | |
|
Expansion line card for CCMHB hub |
CCMLB-AA | |
|
1-meter cable for CCMAB and CCMHB |
BN39B-01 | |
|
4-meter cable for CCMAB and CCMHB |
BN39B-04 | |
|
10-meter cable for CCMAB and CCMHB |
BN39B-10 | |
|
Copper-to-single mode fiber optic converter 5V (clock not affected) |
CCMFB-BA | |
|
Rackmount kit (3U) for CCMHB (Memory Channel Hub II); required for mounting in H9A1x cabinets. |
3X-BA61R-MC | |
|
Power cord for rackmount CCMHB hub |
BN35S-02 | |
|
|
||
| MEMORY CHANNEL Power Cords | Australia, New Zealand, China (8121-0838) | 3R-A6023-AA |
| Central Europe | BN19C-2E | |
| Denmark (103541-481) | BN19K-2E | |
| Egypt, India (103541-AR1) | BN19S-2E | |
| Ireland, United Kingdom | BN19A-2E | |
| Israel | 3R-A6883-AA | |
| Italy (103541-461) | BN19M-2E | |
| Japan, 2.5-meter, Dentori approved | 3X-BN46F-02 | |
| Switzerland (103541-511) | BN19E-2E | |
| NOTE: When using
MEMORY CHANNEL, refer to the TruCluster QuickSpecs for configuration guidelines
and restrictions: http://www.compaq.com/products/quickspecs/division/10657.html The MEMORY CHANNEL controller, CCMAB-AA, must be revision D01 or later. NOTE: This Web Site is available in English only. |
||
|
|
||
| Step 10 - Storage Adapters/Controllers - Mandatory |
||
|
|
||
| NOTE: Refer to the following chart when configuring adapters, shelves, and disks. | ||
|
|
|
AlphaServer ES45 Configuration Chart for Storage Adapters
|
|||||
| Storage Adapters | Shelf | Disk Drives | Tru64 UNIX | OpenVMS | |
| 3X-KZPCA-AA | BA610-6D DS-SL13R-xx 3R-A4075-AA/3R-A4076-AA |
3R-A0xxx-AA 1-inch
Universal 3R-A1xxx-AA 1-inch Universal 3R-A3xxx-AA 1-inch Universal |
V5.1A | V7.3 | |
| 3.3/5 V | 33 MHz | ||||
| 3X-KZPEA-DB | BA610-6D DS-SL13R-Bx 3R-A4075-AA/3R-A4076-AA |
3R-A0xxx-AA 1-inch
Universal 3R-A1xxx-AA 1-inch Universal 3R-A3xxx-AA 1-inch Universal |
V5.1A | V7.3 | |
| 3.3/5 V | 33 MHz | ||||
| * Requires 3X-DWZCV-BA/CA, HVD-to-LVD converter | |||||
|
RAID Controller
|
|||||
| 3X-KZPDC-BE/DF | BA610-6D DS-SL13R-xx 3R-A4075-AA/3R-A4076-AA |
3R-A0xxx-AA 1-inch Universal 3R-A1xxx-AA 1-inch Universal 3R-A3xxx-AA 1-inch Universal |
V5.1B/V5.1A | V7.3-1 | |
|
|
Maximum # Supported | |||||
|
|
Tru64 UNIX | Open VMS |
PCI Slot | |||
|
SCSI
|
PCI 2-port Ultra3 (LVD2) SCSI adapter, 64-bit/66-MHz dual-channel
(uses one PCI slot); includes internal 68-pin and external 68-pin VHDCI
connectors; requires 3X-BC56J-xx cable to connect adapter to DS-SL13R-Bx
shelf; supports internal SDLT tape drives and external SDLT tape libraries.
HSZxx RAID controllers not supported. Supports dual-bus (Models 4354R
and 4454R) and single-bus (Models 4314R and 4414R) shelves with 3X-KZPEA-DB
adapter. Tru64 UNIX requires graphics adapter to run console utilities
(RUN BIOS).
MSA30 enclosures (Models 4414R and 4454R) are not supported in shared SCSI configurations. 3X-KZPEA-DB adapter supports shared SCSI under Tru64 UNIX V5.1B and TruCluster V5.1B with Initial Patch Kit installed; supports maximum of two nodes per shared bus; requires 3X-BN55A-01 Y-cable and connector plug assembly, and 3X-H32CT-AA external LVD terminator per shared bus. NOTE: Tru64 UNIX Initial Patch Kit for V5.1B is located at: http://ftp1.support.compaq.com/public/unix/v5.1b |
6
|
6
|
3.3/
5 V |
66 MHz
|
3X-KZPEA-DB
|
|
|
Ultra160 cable, VHDCI to VHDCI (341174-B21 - 6-feet, 341175-B21
- 12-feet, 164604-B21 - 24-feet)
xx = 02 (6-feet), 03 (12-feet), 04 (24-feet) |
|
|
|
|
3X-BC56J-xx
|
|
|
PCI 1-port Ultra2 (LVD) SCSI adapter, 32-bit/33-MHz, single-channel
(uses one PCI slot); includes internal 68-pin and external 68-pin HD connectors;
order BN38C-xx cable to connect adapter to Ultra3 shelf, or order VHDCI
converter (BN38E-0B) for use with included cable; HSZxx RAID controllers
not supported. No support for shared SCSI.
|
6
|
6
|
3.3/
5 V |
33 MHz
|
3X-KZPCA-AA
|
|
|
68-pin HD male-to-VHDCI male UltraSCSI cable;
xx = 02, 03, 05, 10, 20 meters |
|
|
|
|
BN38C-xx
|
|
|
|
Fibre Channel
|
PCI-X 64-bit 144-MHz 2-GB StorageWorks Fibre Channel Host
Bus Adapter - FCA2684 - single channel
NOTE: For configuration details refer to the Supported Options List at http: http://h18002.www1.hp.com/alphaserver/ options/ases45/ases45_options.html The following pointer also provides additional information regarding this FCA: http://h18006.www1.hp.com/products/ storageworks/fca2684/index.html |
6 | 6 | 3.3/ 5 V |
66 MHz |
DS-A5132-AA
|
|
|
PCI-X 64-bit 144-MHz 2-GB StorageWorks Fibre Channel Host
Bus Adapter - FCA2684 - dual channel
NOTE: For configuration details refer to the Supported Options List at http://h18002.www1.hp.com/alphaserver/ options/ases45/ases45_options.html The following pointer also provides additional information regarding this FCA: http://h18006.www1.hp.com/products/ storageworks/fca2684/index.html |
4 | 4 | 3.3/ 5 V |
66 MHz |
DS-A5134-AA
|
|
|
See Fibre Channel cables and switches, Step 11
|
|
|
|
|
|
|
Multi-function Module
|
PCI 32-bit, 33-MHz multi-function (single-port 10/100
Ethernet UTP/RJ45, Ultra2 LVD SCSI, and 2D graphics) adapter. Model 1B
requires installation on PCI Bus 0 in slots 1 or 2; Models 2B and 3B require
installation on PCI Bus 0 in slots 3, 6, 9, or 10
NOTE: Tru64 UNIX V5.1A requires Patch Kit 3: T64V51AS0003-20010413.tar. Only one 3X-KZPEA-DB allowed on same PCI bus; no multi-head graphics support Use BN25G, BN26M, BN24Q, or BN28Q twisted pair RJ45 cables. |
1
|
1
|
5 V
|
33 MHz
|
3X-DEPVZ-AA
|
|
|
3X-DEPVZ-AA specific-use 3-meter LVD2 SCSI cable
|
|
|
|
|
BN37A-03
|
|
|
|
RAID
|
PCI 2-port PCI to Ultra3, 64-bit, 66 MHz, LVD backplane
RAID controller with 128-MB cache (uses one PCI slot); requires connection
to DS-SL13R-xx shelves or BA610-6D card cage.
NOTE: Tru64 UNIX requires V5.1B and TruCluster V5.1B (non- shared buses only) with Initial Patch Kit: T64V51BV1AS0001-20021229.tar Tru64 UNIX requires V5.1A with Initial Patch Kit: T64V51AV21AS0004-20030206.tar NOTE: No host-based volume shadowing or shared bus support under OpenVMS. |
6 per
system, 3 per PCI bus |
6 per
system, 3 per PCI bus |
3.3/
5 V |
66 MHz
|
3X-KZPDC-BE
|
|
|
PCI 4-port PCI to Ultra3, 64-bit, 66 MHz, LVD backplane
RAID controller with 256-MB cache (uses one PCI slot); requires connection
to DS-SL13R-xx shelves or BA610-6D card cage.
NOTE: Tru64 UNIX requires V5.1B and TruCluster V5.1B (non-shared buses only) with Initial Patch Kit: T64V51BV1AS0001-20021229.tar Tru64 UNIX requires V5.1A with Initial Patch Kit: T64V51AV21AS0004-20030206.tar |
6 per
system, 3 per PCI bus |
6 per
system, 3 per PCI bus |
3.3/
5 V |
66 MHz
|
3X-KZPDC-DF
|
|
U320 LVD SCSI Backplane Raid Controller, 64 bit, 2 Channel
|
6 per system, 3 per PCI bus |
3.3/ 5 V |
66 MHZ |
3X-KZPEC-BF
|
||
|
U320 LVD SCSI Backplane Raid Controller, 64 bit, 4 Channel
|
6 per system, 3 per PCI bus |
3.3/ 5 V |
66 MHz |
3X-KZPEC-DG
|
|
HVD to LVD Converters
|
HVD (High Voltage Differential) adapters and LVD (Low Voltage Differential)
devices are normally incompatible due to their different signaling voltage
levels. This incompatibility does not allow direct communication between
the different technologies. The HVD to LVD converter allows connectivity
between legacy HVD Host Bus Adapters and today's LVD devices. The converter
provides:
|
|
|
|
HVD to LVD one-port converter
|
3X-DWZCV-BA
|
|
|
HVD to LVD two-port converter
|
3X-DWZCV-CA
|
|
|
| Step 11 - Storage Devices - Optional |
||
|
|
| Step 11a - Tape Devices | ||
|
For detailed tape drive information see http://www.compaq.com/products/storageworks/sitemap.html#tapedrives
|
||
|
|
||
| DAT Tape Drives (Internal) |
|
|
| DAT 40-GB LVD internal tape drive (C5686C) | 3R-A6831-AA | |
| DAT 72-GB LVD internal tape drive (Q1522B) | 3R-A6663-AA | |
| 1-meter Ultra2 68-pin LVD cable with two connectors, multimode terminator and two wide-to-narrow adapters | 3X-BN46M-01 | |
|
|
||
| DAT Tabletop Tape Drives | DAT 40-GB LVD tabletop tape drive with North America power cord | C5687D |
| DAT 72-GB LVD tabletop SCSI tape drive with 120V North America power cord, carbon black | Q1523B | |
|
|
||
| DAT Hot-plug Tape Drive | DAT 40-GB hot-plug LVD tape
drive (Q1546A), uses two slots in BA610-6D or 43xxx shelves (cannot be sold
in Europe) |
3R-A4745-AA |
| DAT 72-GB hot-plug LVD tape drive (Q1529A), uses two slots in BA610-6D or 43xxx shelves (cannot be sold in Europe) | 3R-A4547-AA | |
|
|
||
| DAT Autoloaders | DAT 20/40-GB auto loader external | AE313A |
|
|
||
| DLT/SDLT Tape Drives (Internal) |
|
|
| VS160 HH DLT 80/160-GB tape drive | A7569B | |
| SDLT 600-GB 32MB/s tape drive | A7518B | |
|
|
||
| DLT/SDLT Tabletop Tape Drives | SDLT 600--GB external tape driveNA | A7519B |
| SDLT 600GB external tape drive, WW | A7520B | |
| VS160 HH DLT 80/160GB tape drive, external NA | A7570B | |
| VS160 HH DLT 10/160GB tape drive, external WW | A7571B | |
|
|
||
| 3U Rackmount Tape Drive Enclosure | 3U LVD Rackmount Tape Drive Enclosure for use in M-Series Cabinets and Series 10000 Cabinets, 0 drives, carbon black |
274338-B22 |
| Rackmount Kit for H9Axx M-Series Cabinets, carbon black required for mounting 3U Rackmount Tape Drive Enclosure in M-Series cabinet | 3R-A3804-AA | |
| NOTE: The 3U Rackmount Tape Enclosure supports up to four internal half-height removable devices, or up to two full-height devices; select up to four DAT devices or two DLT/SDLT devices with 3U Rackmount Tape Enclosure (274338-B22) or select one of the preconfigured configurations listed below. | ||
|
|
||
| Step 11b Modular Data Routers | ||
|
|
| Network Storage Routers | NOTE: | |
|
||
| e1200-320 One Fibre Channel x 2 LVD FC to SCSI Data Router, Tru64 UNIX and OpenVMS | AD577A | |
| e2400160 One Fibre Channel x 4 LVD FC to SCSI Data Router with card cage, Tru64 UNIX and OpenVMS | AA960A | |
| NSR e2400 One Fibre Channel x 4 LVD FC to SCSI Data Router with no card cage, Tru64 UNIX and OpenVMS | AA928A | |
| e1200-320 One Fibre Channel x 2 LVD FC to SCSI Data Router, Tru64 UNIX and OpenVMS | AD576A | |
|
|
||
| Step 11c External Storage Solutions/Controllers | ||
|
|
| Enterprise Virtual Array 5000 |
ES45 servers support HP Enterprise Virtual
Array 5000 (EVA5000) StorageWorks products running Tru64 UNIX and OpenVMS. The EVA5000 is available in pre-defined configurations with controllers and/or expansion configurations without controllers. The EVA5000 also offers a pre-defined configuration that is optimized for High Performance Technical Computing (HPTC) environments. For ordering information and configuration rules, refer to the EVA5000 QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/11006_div/11006_div.html |
|
|
|
| Enterprise Virtual Array 3000 | ES45 servers support HP Enterprise Virtual
Array 3000 (EVA3000) StorageWorks products running Tru64 UNIX and OpenVMS.
Available in one of four integrated "independent bundle" configurations,
the EVA3000 includes one pair of HSV100 controllers, two Fibre Channel drive
enclosures and 8 to 16 Fibre Channel disk drives (bundle dependent). The
EVA3000 is a full 2-Gb end-to-end Fibre Channel Array solution, which operates
in 1-Gb, 2-Gb, or mixed 1-Gb/2-Gb SAN fabrics. For ordering information
and configuration rules, refer to the EVA3000 QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/11619_div/11619_div.html |
|
|
|
| Modular SAN Array 1000 (msa 1000) | Modular SAN Array 1000, supported
on Tru64 UNIX and two-node clusters (maximum); supported with DS-A5132-AA
and DS-A5134-AA adapters; requires connection via a switch - no direct connect;
no support for FC arbitrated loop Tru64 UNIX V5.1A requires Patch Kit 4: T64V51AB21AS0004-20030206.tar Tru64 UNIX V5.1B requires Patch Kit 1: T64V51BB03AS0001-20021229.tar OpenVMS V7.3-1 requires TIMA Kit: VMS731_mSA1000-V0100 OpenVMS V7.3 requires TIMA Kit: VMS73_FIBRE_SCSI-V0500 OpenVMS V7.2-2 requires TIMA Kit: VMS722_FIBRE_SCSI-V0400 HP recommends OpenVMS customers run the default msa1000 cache settings at 50% read cache and 50% write cache; if a change to the default cache is required, msa1000 cache must be set to 50% write cache or higher (lower than 50% write cache is not supported) NOTE: Requires M-Series Rack Kit. |
201723-B22
|
| M-series Rack Kit |
313877-B21
3R-A5281-AA |
|
|
|
||
| StorageWorks Disk Array Family |
NOTE: The HP StorageWorks Disk Array Family, specifically
the XP128 and XP1024, are supported on AlphaServer ES45 systems. For product
and ordering information, refer to the following Web pages:
http://www.hp.com/products1/storage/products/disk_arrays/highend/xp1024/index.html http://www.hp.com/products1/storage/products/disk_arrays/highend/xp128/index.html The following part numbers have been assigned for reference purposes only: |
| 3R-A4417-AA | A7876A | XP128 Disk Array Control Frame | |
| 3R-A4418-AA | A7906A | XP1024 Disk Array Control Frame | |
| AE001A | XP12000 Disk Array Control Frame | ||
|
|
|||
| Step 12 - Graphics Adapters - Optional | ||
|
|
||
|
||
|
|
| Maximum # Supported | ||||||
| Tru64 UNIX | Open VMS |
PCI/ AGP Slot |
||||
|
2D/3D Graphics
|
RADEON 7500 PCI 3D graphics
accelerator; Tru64 UNIX: Requires V5.1B with latest patch kit. Dual head on first card only (unique video DVI port for 2D or 3D. OpenVMS: Requires V7.3-1 with TIMA Kit: DEC-AXPVMS-VMS731_GRAPHICS-V0300-4.PCSI or latest version. Dual head on first card only (cloned video using DVI port for 2D or 3D. NOTE: For multi-head support, refer to Read Me First document/Release Notes. Do not mix with other graphics cards. |
4 - (2D only) 1 - 3D |
4 - 2D/3D | 3.3/ 5 V |
66 MHz | 3X-PBXGG-AA |
|
|
RADEON 7500 AGP 2D/3D graphics
accelerator; Tru64 UNIX V5.1B with latest patch kit: Tru64 UNIX supports
a maximum of 4 graphics heads when configured with additional RADEON PCI
cards (3X-PBXGG-AA) OpenVMS requires: DEC-AXPVMS-VMS731_GRAPHICS-V0200-4.PCSI or latest version NOTE: Can only operate in Model 1B in slot 3; supports 2X mode only; do not mix with other graphic card types. |
1 | 1 | 1.5 V | 4X | 3X-PBXGG-AB |
|
2D
|
PCI 32-bit, 33-MHz multi-function (single-port 10/100
Ethernet UTP/RJ45, Ultra2 LVD SCSI, and 2D graphics) adapter. Model 1B
requires installation on PCI Bus 0 in slots 1 or 2; Models 2B and 3B require
installation on PCI Bus 0 in slots 3, 6, 9, or 10.
NOTE: Tru64 UNIX V5.1A requires Patch Kit 3: T64V51AS0003-20010413.tar Only one 3X-KZPEA-DB allowed on same PCI bus; no multi-head graphics support; TruCluster support restricted to non-shared SCSI buses only. Use BN25G, BN26M, BN24Q, or BN28Q twisted pair RJ45 cables. |
1 | 1 | 5 V | 33 MHz | 3X-DEPVZ-AA |
|
Step 13 - Monitors |
|
|
|
|
|
|
|
|
|
| CRT Monitors | V7600 17-inch (16-inch viewable image size) 0.24mm FST multi-frequency color monitor, 2-tone (carbon/silver), VGA to 1024 x 768 @85 Hz, MPRII/TCO 99/Energy Star Compliant, Northern Hemisphere with NA power cord, VGA cable |
3R-A5853-AA
|
| Same as above, with Euro power cord |
3R-A5854-AA
|
|
| Same as above, Taiwan, NA power cord |
PF996AA#AB0
|
|
| Same as above, with PRC power cord, CCIB |
3R-A5857-AA
|
|
| Same as above, Southern Hemisphere with Australia/New Zealand power cord |
PF996AA#ABG
|
|
|
|
||
| Flat Panel Monitors | L2065 20" (20.1" viewable
image area) flat panel monitor 0.255mm pixel pitch, 1600 x 1200 @60 Hz,
A + D, TCO 03, Energy Star compliant, 4 video input connectors, (VGA, DVI-I,
composite video and s-video), NA power cord, VGA and DVI-I cables |
3R-A6701-AA
|
| L2035 20" (20.1" viewable
image area) flat panel monitor 0.255mm pixel pitch, 1600 x 1200 @60 Hz,
A + D, TCO 03, Energy Star compliant, 4 video input connectors, (VGA, DVI-I,
composite video and s-video), Euro power cord, VGA and DVI-I cables |
3R-A6702-AA
|
|
| L1955, 19" (19" viewable image size) TFT flat panel monitor, 0.294mm pixel pitch, 1280 x 1024 @60Hz, multi-mode support, MPRII/TCO 03/Energy Star compliant, one VGA, one DVI-I input connector. NA power cord, VGA and DVI-D cables |
PD974AA#ABA
|
|
| L1955, 19" (19" viewable image size) TFT flat panel monitor, 0.294mm pixel pitch, 1280 x 1024 @60Hz, multi-mode support, MPRII/TCO 03/Energy Star compliant, one VGA, one DVI-I input connector. Euro power cord, VGA and DVI-D cables |
PH466A#ABB
|
|
| L1506, 15." (15" viewable image size) TFT flat panel monitor, 0.297 mm pixel pitch, 1024 x 768 @60 Hz, multi-mode support, MPRII/TCO99/Energy Star compliant, NA power cord, VGA cable |
3R-A6515-AA
|
|
| L1530, 15." (15" viewable image size) TFT flat panel monitor, 0.297 mm pixel pitch, 1024 x 768 @60 Hz, multi-mode support, MPRII/TCO99/Energy Star compliant, Euro power cord, VGA cable |
3R-A6516-AA
|
|
|
|
||
| Flat Panel Monitor Rack Mountable | TFT7210R 17" (17" viewable image area) 1U rack-mount flat panel display, 0.264mm pixel pitch, 1280 x 1024 @60/75 Hz, high and low voltage power cords, worldwide |
3R-A5187-AA
|
|
|
||
| Video Extension Cable | 6-foot/1.8-meter video extension cable optional |
BN39C-02
|
|
|
||
| Monitor Power Cords | North American, 120 V, 75-inch |
BN26J-1K
|
| Australia, New Zealand, China, 2.5-meter |
3R-A6023-AA
|
|
| Central Europe, 2.5-meter |
BN19C-2E
|
|
| Denmark, 2.5-meter |
BN19K-2E
|
|
| Egypt, India, South Africa, 2.5-meter |
BN19S-2E
|
|
| Israel, 2.5-meter |
3R-A6883-AA
|
|
| Italy, 2.5-meter |
BN19M-2E
|
|
| Japan, 2.5-meter, Dentori approved |
3X-BN46F-02
|
|
| Switzerland, 2.5-meter |
BN19E-2E
|
|
| UK, Ireland, 2.5-meter |
BN19A-2E
|
|
|
|
||
| Step 14 - Keyboards, Mouse, Documentation | ||
|
|
| Keyboards - Optional | |
|
|
|
|
|
|
|
Opal
|
Carbon
|
|
|
Keyboard/Language
|
OpenVMS
|
Tru64 UNIX
|
OpenVMS*
|
|
U.S. keyboard
|
3X-LK465-A2
|
3R-A6586-AA
|
3X-LK464-A2
|
|
Arabic keyboard
|
-
|
3R-A6572-AA
|
-
|
|
Belgian keyboard
|
3X-LK465-AB
|
3R-A6573-AA
|
3X-LK464-AB
|
|
BHCSY keyboard
|
-
|
3R-A6574-AA
|
-
|
|
Canadian/English keyboard
|
3X-LK465-AQ
|
-
|
3X-LK464-AQ
|
|
Canadian/French keyboard
|
3X-LK465-AC
|
3R-A6575-AA
|
3X-LK464-AC
|
|
Cyrillic keyboard (Russian)
|
3X-LK465-BT
|
3R-A6576-AA
|
3X-LK464-BT
|
|
Czech keyboard
|
3X-LK465-BV
|
3R-A6577-AA
|
3X-LK464-BV
|
|
Danish keyboard
|
3X-LK465-AD
|
3R-A6578-AA
|
3X-LK464-AD
|
|
Dutch keyboard
|
3X-LK465-AH
|
3R-A6579-AA
|
3X-LK464-AH
|
|
Finnish keyboard
|
3X-LK465-AF
|
3R-A6580-AA
|
3X-LK464-AF
|
|
French keyboard
|
3X-LK465-AP
|
3R-A6581-AA
|
3X-LK464-AP
|
|
German keyboard
|
3X-LK465-AG
|
3R-A6582-AA
|
3X-LK464-AG
|
|
Greek keyboard
|
3X-LK465-BH
|
3R-A6583-AA
|
3X-LK464-BH
|
|
Hebrew keyboard
|
3X-LK465-AT
|
3R-A6584-AA
|
3X-LK464-AT
|
|
Hungarian keyboard
|
3X-LK465-BQ
|
3R-A6585-AA
|
3X-LK464-BQ
|
|
International keyboard
|
-
|
3R-A6586-AA
|
-
|
|
Italian keyboard
|
3X-LK465-AI
|
3R-A6587-AA
|
3X-LK464-AI
|
|
Japanese keyboard
|
-
|
3R-A6588-AA
|
-
|
|
Korean keyboard
|
-
|
3R-A6589-AA
|
-
|
|
Latin-American keyboard
|
-
|
3R-A6590-AA
|
-
|
|
Norwegian keyboard
|
3X-LK465-AN
|
3R-A6591-AA
|
3X-LK464-AN
|
|
Polish keyboard
|
3X-LK465-BP
|
3R-A6592-AA
|
3X-LK464-BP
|
|
Portuguese keyboard
|
3X-LK465-AV
|
3R-A6593-AA
|
3X-LK464-AV
|
|
Romanian keyboard
|
3X-LK465-BL
|
-
|
3X-LK464-BL
|
|
Simplified Chinese keyboard
|
-
|
3R-A6594 -AA
|
-
|
|
Slovak keyboard
|
3X-LK465-CZ
|
3R-A6595-AA
|
3X-LK464-CZ
|
|
Spanish keyboard
|
3X-LK465-AS
|
3R-A6596-AA
|
3X-LK464-AS
|
|
Swedish keyboard
|
3X-LK465-AM
|
3R-A6597-AA
|
3X-LK464-AM
|
|
Swiss/French keyboard
|
3X-LK465-AK
|
3R-A6598-AA
|
3X-LK464-AK
|
|
Swiss/German keyboard
|
3X-LK465-AL
|
-
|
3X-LK464-AL
|
|
Traditional Chinese keyboard
|
-
|
3R-A6599-AA
|
-
|
|
Thai keyboard
|
-
|
3R-A6600-AA
|
-
|
|
Turkish Q keyboard
|
3X-LK465-BU
|
3R-A6601-AA
|
3X-LK464-BU
|
|
Turkish/F keyboard
|
3X-LK465-BW
|
-
|
3X-LK464-BW
|
|
UK keyboard
|
-
|
3R-A6602-AA
|
3X-LK464-A2
|
|
Yugoslavian keyboard
|
3X-LK465-BY
|
-
|
3X-LK464-BY
|
| *OpenVMS keyboard (3X-LK464-xx) comes with PS/2 and USB connectors |
| Keyboard or Mouse Extension Cable | 6-foot/1.8-meter keyboard or mouse extension cable; to extend both keyboard and mouse order two cables |
3X-BC34A-06
|
|
|
||
| Mouse | 3-button mouse carbon |
3X-PBQWS-PS
|
|
|
||
| Documentation | Additional AlphaServer ES45 System Information Kit (print and CD), Owners Guide, User Interface Guide, and Release Notes |
QA-6E88A-G8
|
|
|
||
Step 15 - Software - Media and documentation required for first system on site |
|
|
|
|
|
| Tru64 UNIX |
|
|
|
|
||
| When using Tru64 UNIX V5.1A | Tru64 UNIX media and online documentation on CD-ROM |
QA-6ADAA-H8
|
| Tru64 UNIX full hard copy documentation |
QA-6ADAA-GZ
|
|
| TruCluster Plus Software Package, licenses for TruCluster Server, Logical Storage Manager and AdvFS Utilities |
QP-6R9AE-AA
|
|
| TruCluster Server License |
QL-6BRAE-AA
|
|
| Logical Storage Manager License |
QL-2GVAE-AA
|
|
| AdvFS Utilities License |
QL-0EGAE-AA
|
|
| Advanced Server for Tru64 UNIX, 25 client concurrent use license |
QL-5U29M-3D
|
|
| Advanced Server for Tru64 UNIX, 50 client concurrent use license |
QL-5U29M-3E
|
|
| Advanced Server for Tru64 UNIX, 100 client concurrent use license |
QL-5U29M-3F
|
|
| Advanced Server for Tru64 UNIX, 250 client concurrent use license |
QL-5U29M-3G
|
|
| Advanced Server for Tru64 UNIX, 500 client concurrent use license |
QL-5U29M-3H
|
|
| Layered products media and documentation for Tru64 UNIX on CD-ROM |
QA-054AA-H8
|
|
| DECnet/OSI extended function license for Tru64 UNIX |
QL-MTKAE-AA
|
|
| DECnet/OSI end-system license for Tru64 UNIX |
QL-MTJAE-AA
|
|
| Open3D for Tru64 UNIX on CD-ROM, includes graphics drivers |
QA-OAFAA-H8
|
|
|
|
||
| OpenVMS |
|
|
| Concurrent Use 1-user license |
QL-MT3AA-3B
|
|
| Concurrent Use 2-user license |
QL-MT3AA-3C
|
|
| Concurrent Use 4-user license |
QL-MT3AA-3D
|
|
| Concurrent Use 8-user license |
QL-MT3AA-3E
|
|
| Concurrent Use 16-user license |
QL-MT3AA-3F
|
|
| Concurrent Use 32-user license |
QL-MT3AA-3G
|
|
| Concurrent Use 64-user license |
QL-MT3AA-3H
|
| Concurrent Use 128-user license |
QL-MT3AA-3J
|
|
| Concurrent Use 256-user license |
QL-MT3AA-3K
|
|
| Traditional unlimited user license |
QL-MT2AE-AA
|
|
| OpenVMS media and documentation on CD-ROM |
QA-MT1AA-H8
|
|
| OpenVMS full hard copy documentation |
QA-001AA-GZ
|
|
| Layered products media and documentation for OpenVMS on CD-ROM, includes Enterprise Integration Server for OpenVMS media and documentation. |
QA-03XAA-H8
|
|
| DECnet extended function license for OpenVMS |
QL-MTGAE-AA
|
|
| DECnet end-system to extended function upgrade license for OpenVMS |
QL-MTHAE-AA
|
|
| OpenVMS Cluster license for Alpha systems |
QL-MUZAE-AA
|
|
| OpenVMS Volume Shadowing license |
QL-2A1AE-AA
|
|
|
|
||
Step 16 - Hardware and Software Support Services for Tru64 UNIX and OpenVMS |
||
|
|
||
|
||
|
|
| HP Care Pack Services |
|
|
|
|
||
| Program
Features |
||
|
|
||
| HP Support Plus |
|
|
|
|
||
| HP Support Plus 24 |
|
|
|
|
||
| HP Proactive 24 |
|
|
|
|
||
| HP Critical Service |
|
|
|
|
||
| Installation |
|
|
|
|
||
| Installation & Startup HP O/S |
|
|
|
|
||
|
HP Care Pack Services for AlphaServer ES45 Systems
(sold via Fusion Order Management System)
|
||||
| 1-year Package ID# | Option ID# | 3-year Package ID# | Option ID# | |
|
AlphaServer ES45 Model 1B
|
||||
|
HP Support Plus
|
HA109A1 |
6JL | HA109A3 |
6JL |
|
HP Support Plus 24
|
HA110A1 |
6JL | HA110A3 |
6JL |
|
HP Proactive 24
|
HA111A1 |
6JL | HA111A3 | 6JL |
|
HP Critical Service
|
HA112A1 | 6JL | HA112A3 | 6JL |
|
AlphaServer ES45 Model 2B, 3B
|
||||
|
HP Support Plus
|
HA109A1 |
6JH | HA109A3 |
6JH |
|
HP Support Plus 24
|
HA110A1 |
6JH | HA110A3 |
6JH |
|
HP Proactive 24
|
HA111A1 |
6JH | HA111A3 |
6JH |
|
HP Critical Service
|
HA112A1 | 6JH | HA112A3 | 6JH |
|
NOTES:
|
|
|
Technical Specifications
|
Tower Configuration |
Dimensions (H x W x D) |
20 x 15.25 x 31 in (50.8 x 38.7 x 78.7 cm) | ||
| Shipping Dimensions | 32.2 x 24 x 40 in (82.48 x 60.2 x 101.6 cm) | |||
| Weight | Typical Configuration | 144.3 lb (65.6 kg) | ||
| Maximum Configuration | 212.8 lb (96.7 kg) | |||
| Shipping Weight | Typical Configuration | 172 lb (78 kg) | ||
| Maximum Configuration | 242 lb (110 kg) | |||
| Clearances | Operating | Service | ||
| Front | 29.5 in (75 cm) | 29.5 in (75 cm) | ||
| Rear | 6 in (15 cm) | 29.5 in (75 cm) | ||
| Left Side | None | 29.5 in (75 cm) | ||
| Right Side | None | None | ||
|
|
||||
|
Pedestal Configuration |
Dimensions (H x W x D) |
30.8 x 20 x 31.75 in (78.2 x 50.8 x 80.6 cm) | ||
| Shipping Dimensions | 42.4 x 39.5 x 23.9 in (107.7 x 100.3 x 60.7 cm) | |||
| Weight | Typical Configuration | 280 lb (127 kg) | ||
| Maximum Configuration | 350 lb (159 kg) | |||
| Shipping Weight | Typical Configuration | 328 lb (149 kg) | ||
| Maximum Configuration | 407 lb (185 kg) | |||
| Clearances | Operating | Service | ||
| Front | 29.5 in (75 cm) | 29.5 in (75 cm) | ||
| Rear | 6 in (15 cm) | 29.5 in (75 cm) | ||
| Left Side | None | None | ||
| Right Side | None | 29.5 in (75 cm) | ||
|
|
||||
|
Rackmount System |
Dimensions (H x W x D) |
13.87 x 17.6 x 30.1 in (35.2 x
44.7 x 76.5 cm) (fits 14 in [8U] standard RETMA cabinet) |
||
| Shipping Dimensions | 28.8 x 24 x 40 in (73.2 x 60.7 x 101.6 cm) | |||
| Weight | When lifting: | Typical Configuration | 110 lb (50 kg) | |
| Maximum | 167.2 lb (76 kg) | |||
| Total added to cabinet (brackets, slides, cables): | Total added to cabinet (brackets, slides, cables) | 130 lb (59 kg) | ||
| Maximum | 202.4 lb (92 kg) | |||
| Shipping Weight | Nominal | 158 lb (72 kg) | ||
| Maximum | 233 lb (106 kg) | |||
| Clearances | Operating | Service | ||
| See specific cabinet requirements | Minimum 4 ft (121.9
cm), 32.4 in (82.2) cm withdrawal on rails |
|||
|
|
||||
|
Cabinet Configuration |
H9A10 M-Series | H9A15 M-Series | Series 10000 Rack (10642) | |
| Dimensions (H x W x D) |
67 x 23.6 x 41.5 in (170 x 60 x 105.4 cm) |
79 x 23.6 x 41.5 in (200 x 60 x 105.4 cm) |
78.7 x 24 x 39.69 in (199.9 x 60.96 x 100.82 cm) |
|
| Shipping Dimensions | 73 x 36 x 48 in (185.5 x 91.5 x 122 cm) |
85 x 36 x 48 in (216 x 91.5 x 122 cm) |
78.7 x 24 x 39.69 in (199.9 x 60.96 x 100.82 cm) |
|
| Weight | Configuration dependent | Configuration dependent | Configuration dependent | |
| Shipping Weight | Nominal: 946 lb (430 kg) | Nominal: 1,056 lb (550 kg) | 284 lb/129 kg (empty) | |
| Maximum: 1,375 lb (625 kg) | Maximum: 1,408 lb (640 kg) | Maximum: 2,000 lb (909.1 kg) | ||
|
|
||||
|
System Unit |
Environmental | |||||
| Temperature | Operating (Tower, Pedestal, Rackmount) | 50° to 95° F (10° to 35° C) | ||||
| Non-operating | 40° to 151° F (40° to 66° C) | |||||
| Storage (60 days) | 40° to 151° F (40° to 66° C) | |||||
| Rate of change | 20° F/hr (11° C/hr) | |||||
| NOTE: Maximum operating temperature at sea level; reduce by 1.8° F (1° C) for each 2,000 ft (600 m) above sea level. | ||||||
| Humidity | Operating | 20% to 80% | ||||
| Non-operating | 20% to 80% | |||||
| Storage (60 days) | 10% to 95% | |||||
| Rate of change | 20% hr | |||||
| Maximum Wet Bulb Temperature | Operating | 82° F (28° C) | ||||
| Storage (60 days) | 115° F (46° C) | |||||
| Maximum Dew Point Temperature | Operating | 36° F (2° C) | ||||
| Heat Dissipation | Nominal | Maximum | ||||
| Tower and Rack | 980W, 3347 BTU/hr | 1300 W, 4,440 BTU/hr | ||||
| Pedestal | 1560W, 5328 BTU/hr | 2400 W. 8,196 BTU/hr | ||||
| H9A10/H9A15 Cabinets | Configuration dependent | 4800 W, 16,392 BTU/hr | ||||
| Air Flow and Quality | Intake location | Front | ||||
| Exhaust location | Rear Tower, Pedestal, Rack; Rear/top H9A10/H9A15 | |||||
| Particle size | N/A | |||||
| Concentration | N/A | |||||
| Altitude (unpressurized) | Operating | 10,000 ft (3,048 m) | ||||
| Non-operating | 40,000 ft (12,192 m) | |||||
| NOTE: Higher altitudes are possible if maximum operating temperature is reduced (see Temperature); other restrictions may apply such as maximum permissible altitude for hard drives. | ||||||
| Acoustics (Declared values per ISO 9296 and ISO 7779) | ||||||
| Acoustics | LWAd3B | LnAm5dBA (bystander position) |
||||
| Tower or Rackmount | Idle | 6.4 | 47 | |||
| Operating | 6.4 | 47 | ||||
| Pedestal | Idle | 6.6 | 48 | |||
| Operating | 6.6 | 48 | ||||
| NOTE:Current values for specific configurations are available, 1 B = 10 dBA. | ||||||
| Vibration | Operating | 10 to 500 Hz 0.1 G peak | ||||
| Non-operating | 1.03 Grms 5-300 Hz | |||||
| Electrical (Power supplies are universal, PFC, auto ranging, 100/240 VAC) | ||||||
| Nominal Voltage (VAC) | 200 to 240 | |||||
| Voltage Range (VAC) (temporary condition) | 180 to 250 | |||||
| Power Source Phase | Single | |||||
| Nominal Frequency (Hz) | 50/60 | |||||
| Frequency Range (Hz) | 47 to 53/57 to 63 | |||||
| Maximum Inrush Current | Tower and Rackmount | Single power cord | 5.6A | |||
| Multiple power cords | 3.6A | |||||
| Maximum VA | 1440 | |||||
| Pedestal | Each power cord | 8.6A | ||||
| Maximum VA | 2070 | |||||
| M-Series Cabinet (configuration dependent) | Nominal voltage (VAC) | 200 to 240 | ||||
| Each power cord | 16A | |||||
| Power Cords | Tower (mandatory) | Up to 3 (Country specific) |
IEC 320 to country-specific |
|||
| Pedestal (mandatory) | 2 (Country specific) |
IEC 320 C13 to country-specific |
||||
| Rackmount (included) | 3 (14 ft 10 in/52 cm) |
IEC 320 C13 to IEC 320 C14 | ||||
| Cabinet (included) | Up to 4 (10 ft /305 cm) |
200-240 V non-removable NEMA L6-20P for North America or 200-240 V non-removable IEC 309 |
||||
| Regulatory | Agency Approvals | UL: Listed to UL1950 3rd edition | ||||
| UL CNL: Certified to CAN/CSA-C22.2 No. 950-1995 |
||||||
| TUV: EN 60950/A11:1997, GS marked | ||||||
| FCC: Part 15.B Class A | ||||||
| IC ICES-003 Class A | ||||||
| CE: EN55022:1998, EN55024:1998, EN61000-3-2:1995, EN61000-3-3:1995 |
||||||
| VCCI:V-3/97.04 Class A | ||||||
| BSMI: CNS13438 Class A | ||||||
| C-Tick: AS/NZS 3548:1995 Class A | ||||||
| Reviewed to | AS/NZ 3260:1993 Australian/New Zealand Standard | |||||
| EN 60950:2000 | ||||||
| IEC 60950:1999, 3rd edition | ||||||
| UL 60950, 3rd edition, 2000 | ||||||
|
|
||||||
| © Copyright 2001-2007 Hewlett-Packard
Development Company, L.P. The information contained herein is subject to change without notice. UNIX is a registered trademark or trademark of The Open Group in the U.S. and/or other countries. The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial errors or omissions contained herein. |